background image

6

370 Encinal, Suite 150

Santa Cruz, Ca  9506

0

P: 888-426-5644 / F: 831-336-9840
www.

hydrologicsystems.com

Feed and Drain Connec

ti

 on

Feed Connec

ti

 on

Note: The feed connec

ti

 on pictured on the box may be di

 erent from what is included 

with the system.

1.  Locate and turn o

  the angle stop valve on the cold water line feeding the sink.  This 

valve will usually be located under the sink on the pipe coming out of the wall. 
 
2.  When the angle stop valve is closed, relieve pressure in the line by opening the cold 
water tap on the sink. 

3.  Disconnect the feed line at the angle stop valve.  With this end of the water line free, 
proceed to Step 4. 

4.  Wrap the threads with Te

fl

 on tape and install the feed connector into the angle stop 

valve.  Then reconnect the cold water feed line to the open end of the feed connector.  
Tighten all connec

ti

 ons securely.

5.  Using the green 1/4” tubing, install the compression nut, plas

ti

 c ferrule and plas

ti

 c 

tube insert.  Secure the tubing into the feed connector.  Tighten the tubing retaining nut 
securely. 

6. A

tt

 ach the small feed valve warning tag from the parts bag to the feed valve.  

7.  A

tt

 ach the Shuto

  Warning label to the system so that it is directly visible. Fill out the 

Date of Installa

ti

 on label and a

tt

 ach to the side of the system.

Drain Connec

ti

 on

Note: The drain saddle assembly must be installed before the 'P' trap.  Do not install the 
drain saddle assembly between the 'P' trap and the wall. 

1. Posi

ti

 on drain saddle assembly (Fig. 3) on drain pipe under sink between the P trap 

and the sink connec

ti

 on.

  

2.  Orient the drain saddle so that the connec tor opening  points in the general direc

ti

 on 

of the planned loca 

ti

 on for the R.O. dispensing faucet. 

3.  Screw the connector nut onto the drain saddle threaded connector loosely (Fig. 4).  
Using the connector opening in  the side of the drain saddle as a guide, drill a 3/8" hole 
through the wall of the drain pipe.  

4.  Remove drain saddle assembly. Place the adhesive foam pad over the 3/8" hole in the 
drain pipe.  Replace the assembly onto the drain pipe, aligning the hole in the drain with 
the hole in the drain assembly.

5.  Tighten the saddle bolts evenly on both sides un

ti

 l the saddle grips the pipe snugly - 

do not over

ti

 ghten.  (Fig. 4)

Fig.  3   

Fig.  4   

Fig. 1

Содержание ecospring

Страница 1: ...uite 103 Santa Cruz Ca 95065 P 888 426 5644 F 831 336 9840 www eco spring com 02 09 Installation Guide Owner s Manual 350 Encinal Street Suite 170 Santa Cruz Ca 95060 P 888 426 5644 F 831 336 9840 www...

Страница 2: ...d water quality These cartridges work together to remove potential contaminants from your tap water and must be replaced every 6 12 months Any significant change in performance of the system should be...

Страница 3: ...damage to the unit due to fire accident negligence act of God or events beyond the control of the Manufacturer are not covered by this warranty Incidental and Consequential Damages The Manufacturer do...

Страница 4: ...e of potential membrane foulants such as Iron Hydrogen Sulfide and Manganese Production 40 GPD 21 6 GPD 151 LPD 81 8 LPD TDS Rejection 95 95 Recovery1 26 3 17 Brine to Product 2 8 1 4 86 1 1 The perce...

Страница 5: ...plastic spacer 2 open end up onto the threaded faucet stem 7 Loosely thread the 3 8 washer 3 and mounting lock nut 4 onto the threaded stem 8 Thread faucet quick connect adapter 5 on to threads of fa...

Страница 6: ...g nut securely 6 Attach the small feed valve warning tag from the parts bag to the feed valve 7 Attach the Shuto Warning label to the system so that it is directly visible Fill out the Date of Install...

Страница 7: ...lorinating agent in order to ensure tank internal cleanliness Also the carbon filter cartridge will release a small amount of carbon fines during the first tankful of flow This flushing procedure will...

Страница 8: ...rs Press top or bottom of cartridge to engage connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between...

Страница 9: ...ly install the retaining clip will result in accidental leaks and flooding 7 Turn on feed water shut o valve and open dispensing faucet 8 Close dispensing faucet after water starts running 9 Observe s...

Отзывы: