New Install - Always Pressure Up Slowly (Follow start up on page 9)
Problem
Cause
Solution
No Clicking
Sound
Fluid not flowing through unit
Are the red plugs at the inlet, outlet and suction tube fitting openings removed?
Is the unit installed backward? The arrow on the unit must point in the direction
of the fluid flow.
If still not clicking, do not open the upper body. Call Hydro Customer Service.
Fluid flowing through unit
Fluid rate is below or exceeds rated service flow of injector.
(see Specifications page 6).
Has the new injector been stored for an extended period? If so, submerge the
injector in room temperature fluid for 24 hours so that the working parts can
reabsorb fluid and swell back to the proper size.
Operating pressure exceeds maximum limit. Install a pressure reducer valve.
(see Specifications page 6).
On/Off Lever in off position. Place the On/Off lever switch to the ON position.
By-pass valve (A) not closed. Check and set valve to the CLOSED position.
Problem
Cause
Solution
No Clicking
Sound
Main Piston Assembly #9 worn
Replace # 9 Main Piston Assembly. Clean fluid filter.
Cover #1 or main body #40 worn
or scored
Install or clean fluid filter.
On/Off Lever in off position
Place the On/Off lever switch to the ON position.
By-pass valve (A) open
Set Valve (A) to the closed position.
Dirty or plugged inlet filter
Ensure mesh size is correct for proper filtration. Clean filter.
#17 Worn or not seated properly
Re-seat #17 or replace.
Clicking Sound
No Suction
Of Solution
Cylinders #7 or #68 worn
Replace.
Dosage piston/gasket (WSP model)
#44 (0.3% model #51) worn or
installed incorrectly
Replace. Ensure during maintenance replacement that #44 dosage
piston was installed correctly flared-end up.
O-ring retainer #15 installed incorrectly Install correctly.
O-ring seat #14 or dosage piston/
gasket (WSP model) #44 (0.3% model
#51) damaged
Replace.
#17 O-ring worn and/or loose
Replace.
Suction tube #25 or suction tube
fitting #11 cracked, leaking or
clogged suction tube filter
Replace and/or clean as necessary.
Check valve #13 leaking
Clean & replace as necessary.
Clicking Sound.
Under Injecting
#44 (0.3% model #51) Dosage Piston/
Gasket (WSP model) worn
Replace.
#7 (#68 - 0.3%) Inner Cylinder worn
Replace.
Unit operates at high-flow and
not at low flow
Replace #17 O-ring.
Main Piston Assembly #9 worn
Replace # 9 Main Piston Assembly. Clean fluid filter.
Cover #1 or main body #40 worn
or scored
Install or clean fluid filter.
Fluid
Re-filling
Solution Tank
Check valve #13 leaking
Check seat area on suction tube fitting #11. Check valve and seal must fit
loose in the suction tube fitting. Clean seal and inside fitting for debris.
Washer seal on #13 is swollen
or chemical attack
Replace with new check valve assembly.
Injector in Operation or After Scheduled Maintenance
Troubleshooting