TO CARE FOR THE RO SYSTEM

The components of the RO system are designed to function with 

minimal maintenance. However, the membrane elements and pre-

filter will need to be replaced on a regular schedule.
For optimal performance the system should be flushed for 2 minutes if 

periods of inactivity that extend past six hours.

REPLACEMENT OF PRE-FILTER 

The carbon pre-filter reduces sediment and certain chemicals, such 

as chlorine, from the water. Depending on water use and the amount 

of impurities, this filter should be replaced a minimum of 2,000 gallons 

of purified water produced.
Applications using more than an average of 20 gallons purified water 

per day should install the optional Pre-Evolution high capacity pre-

filter to further reduce chlorine, sediment, and other contaminants.

REPLACEMENT OF RO MEMBRANE ELEMENTS

The functional life of the RO membrane elements will vary based 

on feed water quality. Product water should be tested periodically 

to verify the membrane elements are performing properly. For most 

applications, the RO membrane elements should be replaced every 6 

months to two years.

NOTE: Softened water is recommended for optimal system 

performance and RO membrane element life.

 
 
 
 
 
 
 
 
REPLACEMENT OF THE PRE-FILTER,  
AND RO MEMBRANE ELEMENTS

Turn off the water supply to the RO System.  

1. 

Reduce system water pressure by opening the included shut off 

2. 

valve or optional float valve.

CAUTION: 

  Even with the water supply turned off the membrane and 

pre-filter sumps will contain a considerable amount of 

water. By positioning the RO assembly in a sink or tub, 

most of the water will be contained.

Disconnect locking bar and place the fittings (with tubing still 

3. 

connected) into a tub or bucket.

Move system into a contained area, such as a sink or tub.

4. 

Remove the support leg from the three sumps and unscrew the 

5. 

top sump as shown to access the pre-filter. The support leg 

functions as a wrench to loosen the sump, Figure 13.

NOTE: There is no need to disconnect tubing from fittings on the 

manifold. Remove locking bar and pull fittings out. Lubricate 

O-rings with silicone prior to re-assembly.

NOTE: If changing only the pre-filter the other sumps do not need 

to be removed. If changing the membrane elements, the pre-

filter should also be changed.

Remove exhausted pre-filter and discard.

6. 

CAUTION: 

  The person handling the filters and membrane elements 

must have clean hands to keep the system sanitized.  The 

use of sterile/latex gloves is recommended.

 

Figure 7 

10

Содержание EVOLUTION-RO1000

Страница 1: ...Installation Maintenance Manual ...

Страница 2: ...______________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ _________________________________...

Страница 3: ...se out the preservative The preservative is not harmful but makes the product water taste objectionable Rinsing the membrane also acts as a performance conditioner All new membranes will reach their stable maximum performance after 8 hours of rinsing THE BASIC REVERSE OSMOSIS SYSTEM Your Reverse Osmosis System is a water treatment unit It uses water pressure to reverse a natural physical process c...

Страница 4: ... 8 BLACK TUBING 10 ft PN 25045 3 8 BLUE TUBING 10 ft PN 25050 1 2 WHITE TUBING 6 ft PN 25006 SILICONE LUBRICANT FEED INLET DISCONNECT ELBOW WHITE PN 23075 1 pc PURIFIED WATER DISCONNECT ELBOW BLUE PN 23100 1 pc SILICONE LUBRICANT PACK PN 23110 6 pcs O RINGS FOR MEMBRANE STEM PN 23095 4 pcs CARBON PRE FILTER PN 22043 1 pc GARDEN HOSE INLET FITTING PN 12015 1 pc INLINE SHUT OFF VALVE PN 14265 1 pc N...

Страница 5: ...hookup to a variety of feed sources The feed water valve should be located as close to the manifold assembly as possible USE A POTABLE COLD WATER SUPPLY ONLY Softened water is preferred as it will extend the life of the RO membrane elements Other forms of pre filtration may be necessary depending on quality of incoming water THE BASIC REVERSE OSMOSIS SYSTEM cont Drain Point A suitable drain point ...

Страница 6: ... 1 2 White Drain 3 8 Black Purified Water 3 8 Blue Feed Water Valve Cold Water Line Only Feed Pressure Gauge Optional Pre Evolution Pre Filter Pure Water Storage Tank To Point of Use Optional 3 8 Float Valve Typical Light Commercial Installation with Storage Tank 5 ...

Страница 7: ...The installer will determine type of valve that will be used Install a valve on the cold water supply pipe to adapt 1 2 inch OD tubing If threaded fittings are used be sure to use pipe joint compound or Teflon tape on outside threads Turn the valve off Step 2 Direct black drain line to an appropriate drain location or install optional drain adapter The optional 3 8 quick connect drain adapter must...

Страница 8: ...r proper system performance the inlet feed pressure must be between 40 psi 2 76 bar and 80 psi 5 52 bar when the system is in operation Insert the short length of tubing into the white elbow connector Then install pressure gauge w T fitting Then install long length of white tubing to other end of pressure gauge T fitting Inline Shut off Valve The supplied 3 8 inline shut off valve is designed to b...

Страница 9: ... O ring contact surfaces in the 3 manifold ports and 2 RO membrane locations Figure 10 Follow Figure 11 and lubricate the filter seat and the flat surface below the threads for the 3 sump locations Use a complete packet of silicone for each sump location NOTE To properly lubricate the O ring contact area a film of clean silicone grease is applied The film should cover all of the surface area that ...

Страница 10: ...ied The film should cover all of the surface area that the O ring will slide over and seal with Do not use grease containing petroleum products Securely insert O ring end of membrane elements into manifold 5 Push the membrane straight down into the hole in the manifold Do not twist or rock the membrane when intsalling as this may damage the o rings Remove pre filter from packaging Check that gaske...

Страница 11: ...nded for optimal system performance and RO membrane element life REPLACEMENT OF THE PRE FILTER AND RO MEMBRANE ELEMENTS Turn off the water supply to the RO System 1 Reduce system water pressure by opening the included shut off 2 valve or optional float valve CAUTION Even with the water supply turned off the membrane and pre filter sumps will contain a considerable amount of water By positioning th...

Страница 12: ...fold Lubricate sump O ring with silicone lubricant b With the pre filter element in place screw the sump into c the connection Tighten until it bottoms out Re connect the fittings to the manifold and lock in position with 10 locking bar Re position the assembly and turn the water supply on Check the 11 system for any leaks CAUTION Water may sputter from the air gap until the trapped air is purged ...

Страница 13: ... 78 C Inlet TDS 50 mg L 2 000 mg L Inlet Hardness 0 mg L 0 grain 171 mg L 10 grain Inlet Chlorine 0 mg L 1 0 mg L Inlet Iron 0 mg L 0 1 mg L Inlet Manganese 0 mg L 0 05 mg L Inlet pH 4 10 Inlet Turbidity 0 1 NTU 243 9 9 6 242 5 9 55 89 8 3 53 383 5 15 10 508 9 20 03 268 2 10 56 261 10 27 140 5 51 84 3 3 32 130 4 5 13 59 4 2 34 114 3 4 50 50 8 2 0 25 4 1 0 Figure 9 Dimensions 12 ...

Страница 14: ...ns Leak in product line Find and repair leak Install pressure gauge in product line to help identify a product pressure leak Poor product water quality Water sample taken during system flush Take sample after three minutes of continuous operation Low driving pressure Increase feed pressure Consider pump for low pressure locations Use short tubing runs to decrease flow restriction Increase tubing d...

Страница 15: ...______________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ _________________________________...

Страница 16: ...GL4000442 RevA ...

Отзывы: