LOCATION OF SYSTEM

The reverse osmosis system can be installed under or near a sink or 

any other water supply. The RO assembly can be placed on the sink 

cabinet floor in any other location that does not apply pressure on 

the disconnect elbows or tubing. A nearby suitable drain point is also 

required for the drain (waste) water.

NOTE: Keep the lengths of tubing short.  Longer lengths of tubing will 

decrease inlet pressure and ultimately system performance.  

An optional booster pump can be used on the supply line to 

increase inlet pressure.

NOTE: All plumbing should be done in accordance with state and 

local plumbing codes. 

 

Some codes may require installation by a licensed plumber. 

Check with the local plumbing authority prior to installation.

WARNING:

 All components and tubing should be located in an 

area which is not exposed to freezing temperatures. 

Do not expose unit or tubing to direct sunlight.

Water Supply:

  To provide supply water to the RO system inlet, a 

garden hose connection fitting is included with the system. Other 

types of feed supply fittings are available to allow hookup to a variety 

of feed sources. The feed water valve should be located as close to 

the manifold assembly as possible. 

USE A POTABLE COLD WATER 

SUPPLY ONLY.

 Softened water is preferred as it will extend the life 

of the RO membrane elements. Other forms of pre-filtration may be 

necessary depending on quality of incoming water.

THE BASIC REVERSE OSMOSIS SYSTEM cont.

Drain Point:

  A suitable drain point is needed for reject (waste) water 

from the RO system. A floor drain, laundry tub, standpipe, sump, etc. 

are all acceptable. If discharging into the utility sink or standpipe, 

an air gap of greater than 1/2-inches above the flood rim must be 

provided. 
An optional 3/8” quick connect sink p-trap drain adapter is available 

to install as an optional drain point where codes permit.
Do not connect the system drain line to the dishwasher drain or near 

the garbage disposal. Back pressure from these units may cause the 

air gap to overflow. 

RO Manifold Assembly:

  The RO system can be installed in either a 

horizontal or vertical orientation. Installation in the basement is also 

an option. One possible location is near the laundry/ utility sink where 

cold potable water and drain access are close. The location chosen 

should allow adequate clearance and accessibility for membrane 

element changes.

4

Содержание EVOLUTION-RO1000

Страница 1: ...Installation Maintenance Manual ...

Страница 2: ...______________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ _________________________________...

Страница 3: ...se out the preservative The preservative is not harmful but makes the product water taste objectionable Rinsing the membrane also acts as a performance conditioner All new membranes will reach their stable maximum performance after 8 hours of rinsing THE BASIC REVERSE OSMOSIS SYSTEM Your Reverse Osmosis System is a water treatment unit It uses water pressure to reverse a natural physical process c...

Страница 4: ... 8 BLACK TUBING 10 ft PN 25045 3 8 BLUE TUBING 10 ft PN 25050 1 2 WHITE TUBING 6 ft PN 25006 SILICONE LUBRICANT FEED INLET DISCONNECT ELBOW WHITE PN 23075 1 pc PURIFIED WATER DISCONNECT ELBOW BLUE PN 23100 1 pc SILICONE LUBRICANT PACK PN 23110 6 pcs O RINGS FOR MEMBRANE STEM PN 23095 4 pcs CARBON PRE FILTER PN 22043 1 pc GARDEN HOSE INLET FITTING PN 12015 1 pc INLINE SHUT OFF VALVE PN 14265 1 pc N...

Страница 5: ...hookup to a variety of feed sources The feed water valve should be located as close to the manifold assembly as possible USE A POTABLE COLD WATER SUPPLY ONLY Softened water is preferred as it will extend the life of the RO membrane elements Other forms of pre filtration may be necessary depending on quality of incoming water THE BASIC REVERSE OSMOSIS SYSTEM cont Drain Point A suitable drain point ...

Страница 6: ... 1 2 White Drain 3 8 Black Purified Water 3 8 Blue Feed Water Valve Cold Water Line Only Feed Pressure Gauge Optional Pre Evolution Pre Filter Pure Water Storage Tank To Point of Use Optional 3 8 Float Valve Typical Light Commercial Installation with Storage Tank 5 ...

Страница 7: ...The installer will determine type of valve that will be used Install a valve on the cold water supply pipe to adapt 1 2 inch OD tubing If threaded fittings are used be sure to use pipe joint compound or Teflon tape on outside threads Turn the valve off Step 2 Direct black drain line to an appropriate drain location or install optional drain adapter The optional 3 8 quick connect drain adapter must...

Страница 8: ...r proper system performance the inlet feed pressure must be between 40 psi 2 76 bar and 80 psi 5 52 bar when the system is in operation Insert the short length of tubing into the white elbow connector Then install pressure gauge w T fitting Then install long length of white tubing to other end of pressure gauge T fitting Inline Shut off Valve The supplied 3 8 inline shut off valve is designed to b...

Страница 9: ... O ring contact surfaces in the 3 manifold ports and 2 RO membrane locations Figure 10 Follow Figure 11 and lubricate the filter seat and the flat surface below the threads for the 3 sump locations Use a complete packet of silicone for each sump location NOTE To properly lubricate the O ring contact area a film of clean silicone grease is applied The film should cover all of the surface area that ...

Страница 10: ...ied The film should cover all of the surface area that the O ring will slide over and seal with Do not use grease containing petroleum products Securely insert O ring end of membrane elements into manifold 5 Push the membrane straight down into the hole in the manifold Do not twist or rock the membrane when intsalling as this may damage the o rings Remove pre filter from packaging Check that gaske...

Страница 11: ...nded for optimal system performance and RO membrane element life REPLACEMENT OF THE PRE FILTER AND RO MEMBRANE ELEMENTS Turn off the water supply to the RO System 1 Reduce system water pressure by opening the included shut off 2 valve or optional float valve CAUTION Even with the water supply turned off the membrane and pre filter sumps will contain a considerable amount of water By positioning th...

Страница 12: ...fold Lubricate sump O ring with silicone lubricant b With the pre filter element in place screw the sump into c the connection Tighten until it bottoms out Re connect the fittings to the manifold and lock in position with 10 locking bar Re position the assembly and turn the water supply on Check the 11 system for any leaks CAUTION Water may sputter from the air gap until the trapped air is purged ...

Страница 13: ... 78 C Inlet TDS 50 mg L 2 000 mg L Inlet Hardness 0 mg L 0 grain 171 mg L 10 grain Inlet Chlorine 0 mg L 1 0 mg L Inlet Iron 0 mg L 0 1 mg L Inlet Manganese 0 mg L 0 05 mg L Inlet pH 4 10 Inlet Turbidity 0 1 NTU 243 9 9 6 242 5 9 55 89 8 3 53 383 5 15 10 508 9 20 03 268 2 10 56 261 10 27 140 5 51 84 3 3 32 130 4 5 13 59 4 2 34 114 3 4 50 50 8 2 0 25 4 1 0 Figure 9 Dimensions 12 ...

Страница 14: ...ns Leak in product line Find and repair leak Install pressure gauge in product line to help identify a product pressure leak Poor product water quality Water sample taken during system flush Take sample after three minutes of continuous operation Low driving pressure Increase feed pressure Consider pump for low pressure locations Use short tubing runs to decrease flow restriction Increase tubing d...

Страница 15: ...______________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ ___________________________________________ _________________________________...

Страница 16: ...GL4000442 RevA ...

Отзывы: