Page 3-3 : CTS 450 Owner’s Manual
Hot Carbonating Truckmount System
CTS 450
Notes:
-
The Compressor Valve must be positioned in the PRESSURE RELIEF and
CLEANING MODE switch must be in EXTRACTION MODE during flood
extraction. If the valve is left in the CLEANING MODE, this may cause dam-
age to the air compressor and related components.
-
The Solution Valve must be positioned in the PRIME mode during flood
extraction. If the valve is left in the CLEANING MODE, the system may build
up excessive pressure, which could cause damage to the machine.
Solution Fill Procedure
1. Position Compressor Valve to PRESSURE
RELI
E
F.
2. Remove the lid from the solution tank.
3. Disconnect hoses if necessary.
4. Fill solution tank with solution.
5. Replace the lid on the chemical tank.
6. Reconnect hoses if necessary.
7. Position the Compressor Valve to CLEAN-
ING MODE.
Shut Down
1. Set Compressor Valve to PRESSURE RELIEF.
2. Position cleaning mode switch to EXTRACTION MODE.
3. Lube vacuum blower at blower port. (End of Day)
4. If in use, switch OFF Auto Pump –Out.
5. Disconnect all hoses.
6. Switch engine speed to IDLE mode.
7. Switch OFF ignition.
8. Drain and Flush recovery tank with clean water.
9. Remove and clean filter bag. (End of Day)
Figure 3-3
Содержание CTS 450
Страница 2: ......
Страница 24: ...Page 1 15 CTS 450 Owner s Manual CTS 450Hot Carbonating Truckmount System Figure 1 5 Hard Water Map...
Страница 42: ...Page 4 7 CTS 450 Owner s Manual Hot Carbonating Truckmount System CTS 450 This page intentionally left blank...
Страница 109: ...Page 6 1 CTS 450 Owner s Manual CTS 450Hot Carbonating Truckmount System Figure 6 1 Solution Flow Diagram D 5860 Rev C...
Страница 110: ...Page 6 3 CTS 450 Owner s Manual CTS 450Hot Carbonating Truckmount System Figure 6 1 Solution Flow Diagram D 5860 Rev C...