![HydraMaster Boxxer 423s Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/hydramaster/boxxer-423s/boxxer-423s_owners-manual_2191721055.webp)
8-11: Systems Troubleshooting
Systems Troubleshooting: 8-10
VACUUM SYSTEM
1.0 A weak vacuum at wand. The gauge reads normal.
Possible Cause
Solution
1.1 Blockage in the hoses or
wand tube
Disconnect the hoses and check for an obstruction.
1.2 Excessive length of
hose connected to the
truckmount
Do not attach excessive lengths of hose.
2.0 A weak vacuum
Possible Cause
Solution
2.1 Air leak somewhere in the
vacuum system.
Check the vacuum relief valve for proper adjustment.
Carefully check all the vacuum hoses for a cut or
break.
Check the recovery tank lid gasket.
Make sure the recovery tank drain valve is fully
closed.
2.2 The vacuum blower is
turning too slowly.
Check the rpm of the engine. Adjust as necessary to
3,200 rpm under no vacuum load.
2.3 The vacuum gauge is
defective.
Test the gauge and replace if necessary.
3.0 The vacuum gauge reads too high with no hoses attached
Possible Cause
Solution
3.1
The filter in recovery tank
is clogged.
Remove and clean or replace as necessary.
3.2 The hose from recovery
tank to the vacuum blower
is collapsed internally.
Inspect and replace as necessary.
4.0 Excessive noise produced by the blower
Possible Cause
Solution
4.1 The blower is low on oil.
Inspect the oil levels and replenish as necessary.
Note: Running the blower with low oil levels can cause
severe damage. If this situation occurs the blower
should be inspected by a qualified service technician.
4.2 The vacuum blower has
internal damage.
Refer to a qualified service technician.
5.0 The vacuum blower is locked and will not turn
Possible Cause
Solution
5.1 Truckmount has been
inactive for a period of
time and the blower was
not properly lubricated
prior to final shutdown.
Rust has possibly built up
on the internal surfaces.
Spray penetrating oil into the blower and let sit for
at least 1 hour. Then very carefully use pipe wrench
on the outer diameter of the pulley on the coupler
to attempt to free lobes of the blower. Do not use a
wrench directly on the blower shaft.
If unable to free up the blower in this manner, refer to
a qualified service technician.
5.2 There is internal damage
to the blower.
Refer to a qualified service technician.
6.0 Water in truckmount exhaust
Possible Cause
Solution
6.1 The recovery tank has
been filled with foam or
overfilled with water.
Inspect the recovery tank. If full, drain the tank.
Inspect the high level shutoff switch for proper
operation. Clean or replace the switch as necessary.
If foam is in recovery tank, use defoamer on the
carpet being cleaned.
6.2 Condensation in system.
This will be more common in cool weather and humid
climates. If this is the cause, it should dissipate after
a few minutes of running.
6.3 The heat exchanger is
leaking water.
Inspect and repair or replace as necessary.
Содержание Boxxer 423s
Страница 5: ...Boxxer 423S Owner s Manual vi ...
Страница 15: ...General Information 1 18 ...
Страница 25: ...Cleaning Information 3 10 ...
Страница 29: ...Operating Instructions 4 6 ...
Страница 43: ...6 3 Water and Chemical System Figure 6 1 Flow Diagram View 1 of 3 000 179 045 Rev A ...
Страница 45: ...Water and Chemical System 6 6 ...
Страница 49: ...Electrical System 7 6 ...
Страница 56: ...Systems Troubleshooting 8 12 ...
Страница 85: ...9 56 Assemblies and Parts Lists ...
Страница 87: ...How to Order Parts 10 2 ...
Страница 90: ...Warranty Information 11 4 ...
Страница 92: ...Accessories and Chemical Solutions 12 2 ...