5-9: Machine Maintenance
Machine Maintenance: 5-8
Servicing Valves on the High Pressure Pump
Removing a Valve
1. Remove the valve cap (30 mm) and extract the valve assembly (see Figure 5-1).
2. Remove the valve assembly (retainer, spring, valve plate, valve seat) from the valve
cavity.
3. Remove the O-ring and support from the valve cavity.
4. Examine the O-ring and replace if there is any evidence of cuts, abrasion, or
distortion.
5. Inspect the manifold for wear or damage (see Figure 5-2).
6. Inspect the old valves for wear or damage. Only one valve kit (P/N 000-078-521)
is necessary to repair all the valves in the pump. (The kit includes new supports,
O-rings, valve seat, valve poppet, spring and retainer; all are pre-assembled.)
Figure 5-1. Remove Valve Cap and Valve Assembly
Figure 5-2. Inspect Manifold and Old Valves
7.
Replace the center inlet check valve with a modified check valve
8. Apply O-ring grease to O-rings and install valves (Figure 5-4).
9. Replace valve cap and torque to 95 ft lbs see Figure 5-5).
Figure 5-4. Apply Grease
and Install Valves
Figure 5-5. Replace Valve Cap
and Torque to 95 ft lbs
Figure 5-3.
Replace Center Inlet Check Valve With Modified Check Valve
Modified Check Valve
Содержание Boxxer 423s
Страница 5: ...Boxxer 423S Owner s Manual vi ...
Страница 15: ...General Information 1 18 ...
Страница 25: ...Cleaning Information 3 10 ...
Страница 29: ...Operating Instructions 4 6 ...
Страница 43: ...6 3 Water and Chemical System Figure 6 1 Flow Diagram View 1 of 3 000 179 045 Rev A ...
Страница 45: ...Water and Chemical System 6 6 ...
Страница 49: ...Electrical System 7 6 ...
Страница 56: ...Systems Troubleshooting 8 12 ...
Страница 85: ...9 56 Assemblies and Parts Lists ...
Страница 87: ...How to Order Parts 10 2 ...
Страница 90: ...Warranty Information 11 4 ...
Страница 92: ...Accessories and Chemical Solutions 12 2 ...