CALIBRATION PROCEDURE
1. Fit the S28 die set into the machine.
2. Use a mandrel of known size of 30mm.
3. With mandrel in the machine pump until the maximum pressure has been achieved.
4. Set the calibrator to 2.00 on the dial.
5. Turn adjusting screw (
Item 4 - Fig.4
) at the end of the calibrator rod, until it is level
with the top of the calibrator (
Item 1 - Fig.4
).
6. To check calibration, release pressure and repeat step 3. At maximum pump
pressure the calibrator rod should be level with the top of the calibrator.
+
=
24,10
Die size: 22
Micrometer = 2,10
Swage size
Fig 3
S22