Performing Maintenance
OXiStop OXS-LID
en
Page 88 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
To install the diaphragm proceed as follows:
1.
Clean sealing surface (X) of diaphragm (6.1) completely.
The sealing surface must be free of old sealant residue.
2.
Apply a thin, even layer of HYLOMAR M sealant around sealing
surface (X). The part no. can be found in the spare parts list.
Observe the bleed time in accordance with the
operating instructions.
Use exclusively the recommended sealant to seal the
diaphragm. This is the only way to ensure material
compatibility.
3.
Insert the new diaphragm (6.1) through the opening in the tank and
align it.