Performing Maintenance
OXiStop OXS-LID
en
Page 86 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
To remove the diaphragm, proceed as follows:
1.
Switch off the unit and all its components.
2.
Drain the unit completely – for details see the chapter "Completely
emptying
the hydraulic tank for transport, oil change, etc." on page
3.
Remove the piping between valve block and diaphragm cover (6.2).
Loosen all nuts (6.6) and washers (6.5) of the diaphragm cover (6.2).
4.
Take the diaphragm cover (6.2) off.
5.
Remove diaphragm (6.1) from the diaphragm cage and dispose of it
in an environmentally correct manner.
6.
The removal of the diaphragm is now complete.