Performing Maintenance
OXiStop OXS-LID
en
Page 78 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
To clean/replace the suction strainer, proceed as follows:
1.
Switch off the unit/all components.
2.
Empty the OLF 5 bypass flow filtration unit, as described in chapter
"Replace the filter element on the OLF 5 bypass flow filtration
element" on page 71.
3.
Loosen hose assembly (2.5) and remove the suction strainer (2.42).
4.
Clean the suction strainer (2.42) by washing it out and then blowing it
out with compressed air.
Wear gloves and safety goggles.
5.
Insert the clean/new suction strainer (2.42) with the O-ring (2.41).
6.
Screw together the connector and fasten it tightly.
7.
Cleaning/exchanging the suction strainer is now complete.