Starting up the unit
OXiStop OXS-LID
en
Page 47 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
Starting up the unit
After you have connected the unit and the components hydraulically and
electrically as described in the relevant chapters, start up the unit as follows:
1.
Check that a suitable filter element is installed in all filter housings.
2.
Fill and bleed the unit with oil as described in the chapter "Filling the
hydraulic tank with oil (first filling/oil change)" on page 53.
3.
Check all the settings of the sensors/indicators – see:
- Checking/setting the electronic pressure switch (EDS), see page 80
for details.
- Checking/setting electronic fluid level/temperature sensor HNS, see
page 82 for details.
4.
Switch on the unit's components.
Switching off the unit
To switch off the unit, switch off all of the components such as the OLF 5
bypass flow filtration unit, sensor, etc. or disconnect the electricity to them.
Содержание OXiStop OXS 150LID