8 | Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
68 / 100
MoWa OLF-5 3433222d en-us web
10.
Push the filter bowl with the filter element up into the
mount on the filter head.
11.
Push the housing clamp (1) from the bottom over the fil-
ter bowl to the top over bead on the filter bowl/filter
head.
Tighten the housing clamp in clockwise direction using
an Allen wrench (
= 5 mm). The tightening torque is 5
Nm.
12.
Check the drain plug on the filter bowl for a correct fit
with an Allen key (
= 6 mm).
1