HYDAC FILTER SYSTEMS GMBH
Mounting/installing | 5
MoWa OLF-5Z OLF-10Z 4520794 en-us print
49 / 88
See also
2
Setting the flow control valve [
5.9.1 Filter housing with flow control valve (OLF-xx-E-Z)
The flow control valve on the filter housing keeps the flow rate
constant by means of a control process. The flow rate is al-
most entirely independent of the pressure and viscosity.
The flow rate is factory-set to 5 l/min. The flow control valve's
setting range ranges from 4.0 … 5.2 l/min.
Fig. 15:
Filter housing with flow control valve
Pos. Description
(A) Adjustment screw
(B) lock nut
1
2
3
4
5
6
7
8
A
Содержание OLF-10/Z
Страница 87: ......
Страница 88: ...www hydac com ...