Maintenance and Servicing Manual
FAM 200 FluidAqua Mobil
Remove the retaining screws of the side water cooler
cover paneling.
Remove the cover paneling of the water cooler.
[1]
Open the hose clamp of the forward-flow hose.
Pull off the forward-flow hose [1] off the nozzle.
Open the hose clamp of the return-flow line (on the pump at the front) and pull the return-
flow line off the bend.
Carefully blow out the return-flow line with compressed air (see direction of arrow)
HYDAC Filtertechnik GmbH
en
Page 20
IuW FAM200 3373093a en.doc