15.
(I)
Open the shut-off device at the inlet
IN
slowly to avoid
pressure shocks to the filter and fill the filter housing.
(II)
During the filling process, take note of the vent bore.
(III)
Shut the shut off device at the inlet
IN
as soon as
fluid escapes.
16.
(I)
Screw in the vent screw clockwise using an Allen
wrench
= 10 mm.
Tighten the vent screw with a torque of 20 Nm.
(II)
Open the shut off device at the inlet
IN
.
(III)
Open the shut off device at the outlet
OUT
.
17.
After commissioning, check the filtration unit for leaks.
O
The replacement of the filter element is now complete.
The filter housing is ready for operation.