Page 1: ...Installation Programming and Maintenance User Guide Pure water everywhere ...

Page 2: ...agram Control Unit 20 8 Programming 21 8 1 Systems with copper ION Peroxide Per Cl and Redox rX option 21 8 2 Private swimming pools 23 8 3 Public swimming pools 24 8 4 Other programming 25 9 Oxymatic Start 30 9 1 Automatic and manual position 30 9 2 Programming and start up 30 9 2 1 Voltage of the electrodes Very important 30 9 2 2 Level of Copper in the water 30 9 2 3 pH check out 31 9 1 Interne...

Page 3: ... regulations in accordance with ITC BT standard 031 2002 Electrical and electromagnetic safety standards in accordance with directive 7323 ECC EN61010 1 93 ELECTRICAL SPECIFICATIONS Mod OXYMATIC SMART Power supply 110 250 Vac Operating frequency 50 60 Hz Energy consumption when not running 120 mA Oxidation sequence consumption at 6 amps 350 mA Ionisation sequence consumption at 2 amps 180 mA Opera...

Page 4: ...ted its ability to control many water pollutants but has many side effects harmful to the environment and human health such as trihalomethanes chloramines phenols etc as well as corrosion of pipes aluminum chrome etc not only health professional groups are against chlorine but also the public around the world is beginning to change the rules by eliminating or minimizing the use of toxic chemicals ...

Page 5: ... redox potential OXIDATION REDUCTION POTENTIAL ORP Chemical name Symbol ORP Value 1 Fluorine F2 2 25 2 Hydroxyl Ion OH 2 05 3 Atomic Oxygen O 1 78 4 Ozone O3 1 52 5 Hydrogen Peroxide H2O2 1 30 6 Permanganate KMn2O7 1 22 7 Hypochlorous Ácid HClO 1 10 8 Chlorine Gas Cl2 1 00 9 Oxygen O2 0 94 10 Sodium Hypochlorite NaClO 0 69 Oxidants produced by the system OXYMATIC 3 3 IONIZATION From the copper ele...

Page 6: ... the tendency to corrosion This phenomenon has been tested by ETL Laboratories EPA and developed by OXYMATIC in 1995 Warning In coated liner pools must be especially careful so that the pH exceeds 7 6 and that from this point begins to precipitate copper and by the characteristics of the pool liner can be stained blue and these stains are difficult to remove With any other covering material or mai...

Page 7: ...Installation Programming and Maintenance User Guide Oxymatic Smart V 1 3 2 May 2015 7 4 OXYMATIC S CONTENT 4 1 INCLUDED ITEMS ...

Page 8: ... valves Motor Protection Fastening screws Oxymatic Tools Flow switch 4 3 OPTIONS Redox Regulator Peristaltic Pump Redox Probe Accessories PVC pipe Rx Buffer mV 468 Probe holder Injector Redox Software Peroxide Injection Peristaltic pump Accessories PVC pipe Injector Peroxide Software pH Regulator Peristaltic pump pH probe Accessories PVC pipe Buffer pH7 Buffer 9 pH Probe holder Injector pH softwar...

Page 9: ...Peristaltic pump Cl probe Accessories for free Chlorine regulation Probe holder Injector Free chlorine Software Copper Sensor Cupper probe Cu buffer Copper software Kit Test Copper Solution A Solution B Tube pipe Colors card Ecological Antiscaling Conductivity Probe Vario Flow Level sensor of pH Rx H20 etc Ask for any options to distributor ...

Page 10: ...enance User Guide Oxymatic Smart V 1 3 2 May 2015 10 4 4 OXYMATIC DIMENSIONS Length 345 mm Depth 275 mm High 110 mm Length 456 mm Depth 122 mm High 336 mm Length 440 mm Depth 440 mm High 340 mm 14 Kg It depends on the model and options ...

Page 11: ...lter outlet All pool water will pass through the chamber where the operating titanium electrode continually generates hydroxyl ions This will have the effect of raising the pool water s ORP to the technical limit of the system Taking into account that the titanium electrodes should be installed at the entry of the water and the copper electrodes to the exit of the water Depending on the Oxymatic m...

Page 12: ...fall below 10 as a by pass and in parallel For example we recommend using PVC pipes Pipe 75 mm 1 chamber or 2 in line Pipe 90 to 140 mm minimum 2 chambers in parallel Pipe 140 225 mm minimum 3 chambers in parallel Pipe 225 300 mm minimum 4 chambers in parallel The material of the chamber is compatible with any PVC glue Examples of installations Serial Parallel IN Water entrance Titane electrodes h...

Page 13: ...trodes to introducing into the chamber 5 1 3 Instal the pH Rx and temperature probes with their probe carriers as indicated at the chamber 5 1 4 Instal the flexibles tubes for the dosing pumps included Transparent pipe extraction of chemical products White pipe injection of chemical products Once all components have been installed in the chamber open up and close the valves following the procedure...

Page 14: ...provided as follows PERISTALTIC PUMPS for pH Redox Peroxide Copper Direct outlet to the mains RECIRCULATION PUMP Dry contact The voltage output depends on the mains input If the mains is 117VCA the output to the peristaltic pump will be 117VCA if the mains is 230VAC the peristaltic pump output will be 230VAC OXYMATIC s cut off relay is 4 amps at 230VAC we therefore need to use contactors or motor ...

Page 15: ...Installation Programming and Maintenance User Guide Oxymatic Smart V 1 3 2 May 2015 15 5 3 1 Electrodes Measure Power and Alarms 5 3 2 Performances Auxiliary Outputs ...

Page 16: ...mer of the recirculation pump When the time meter which controls the supply to the main existing pump emits power to start up the pump it will do likewise for the control unit so that it will start up and shut down both systems together 5 5 CONNECTION OF THE CABLES TO OXYMATIC TERMINALS Terminal nº Description 1 2 y 3 Main power connection to the network Max 240V 4 al 12 Alarms 13 al 20 Connection...

Page 17: ...PS For installation of the pH sound chamber and the injection canal one should use the sound holder which is included and then proceed with the order shown in the photo ATTENTION The pH injection canal must be positioned at the end of the water circuit to avoid acid contacting with the electrodes and or different parts of metals filter water pump heat pump exchangers and this could cause deteriora...

Page 18: ...isms bacteria materials or heavy metals In this case the water needs an intensive preparation before OXYMATIC system performance and that water must be completely free of metals bacteria etc Electrical conductivity or TDS total dissolved solids The principle of OXYMATIC based on the hydrolysis determines the conductivity of the pool is an important factor that favors the creation of ions the highe...

Page 19: ... start the Oxymatic system If you have a copper level above 0 7 ppm try to decrease For this we can renew part of the water of the pool with water without copper or use metal sequestering agent If the level of copper is below 0 5 ppm increase copper Recommended by Hydrover Start Oxymatic in manual position Run the copper electrode only Leave your computer running 48 hours straight Measure copper I...

Page 20: ...1 3 2 May 2015 20 7 DIAGRAM CONTROL UNIT Presentation of the Oxymatic and the chamber in the model with without copper Cu Presentation of the Oxymatic and the chamber in the model with copper Cu Presentation of the Oxymatic and the chamber in the model without copper Cu ...

Page 21: ...hing we see is the main screen This screen will give us the starting point for our programming and starting up of the system We inform you that the systems have been previously programmed by the factory So if we do not need to make any additional programming we just have to press the AUTO button and our Oxymatic will work with the established programs 8 1 SYSTEMS WITH COPPER ION PEROXIDE PER CL AN...

Page 22: ...in order to calibrate the pH probe To calibrate the pH probe we must insert our probe at grading solution no 7 Once detected and set the Adjusting value 07 00 pH option will appear We must then cleanse the probe with clean water and insert it into grading solution no 9 Once our probe has been calibrated the Adjusting value 09 00 pH option will be displayed on screen The Calibration finished messag...

Page 23: ...ystem will now work with the new calibration 8 2 PRIVATE SWIMMING POOLS PRE SET program Press the PROG button on the main screen You have the ability to select one of the pre set programs according to water temperatura and conditions You can see this below and select the program that best meets your requirements For the OXYMATIC system to function effectively we need to bear in mind that the daily...

Page 24: ...ODEL VOLTAGE MUST ALWAYS BE UNDER 9 5V WHATEVER THE AMPS If the voltage is 9 5V out some sea salt NaCl directly into the pool 25 kg per 50 m3 volume Recommended water salinity is approximately 600 TDS This adjustment is made only when starting up the system and when salinity decreases owing to a large number of water replacements etc 5 Water conditionning a Effective recirculation full recirculati...

Page 25: ... into operation procedure for the CONTROL of residual Redox and Chlorine In order to maintain a concentration of residual chlorine of 0 5 mg l in a public pool we proceed as follows Fix the LOW set point to 720 mV and the HIGH set point to 300 mV Wait one day and measure the chlorine in the pool with DP1 pellets or drips If the level is low it is necessary to raise the LOW set point from 720 to 74...

Page 26: ...gh the Oxymatic we can do it f rom the main screen by accessing the SET option GENERAL SET TINGS On this screen we will choose HEAT PUMP TEMPERATURE If the option shows OFF you have to press the ON OFF button to activate it We can set the desired temperature from the editable white space of the temperature The following screen will appear Here we can choose the temperature at which the heat pump w...

Page 27: ...urs of operation from the Heat Pump Actuation option To select the time of operation of our heat pump we will act through Heat Pump Actuation The following screen will then appear and will allow us to choose the starting time of the heat pump Then we choose the stop time of our heat pump The heat pump is now programmed to heat the water in our pool Once our programming is completed press the BACK ...

Page 28: ...T option and we will go directly to the modifiable white space of the options Light or Cover We will first change the start time of the lighting or the opening of the pool cover Then we will choose the time to stop the lights or to close the pool cover We have now programmed all the components of our pool For any other type of programming please do not hesitate to contact our Technical Service Sel...

Page 29: ...is recommended that a professional does it Once this action is completed press the BACK button on the main screen and press the AUTO button in order to make the system work with the new parameters Redox SET POINT go to the SET option on the main screen enter the password 1122 and press the editable white boxes 500 and 400 Modify the desired parameters It is recommended that a professional does it ...

Page 30: ... In the case that the voltage of the electrodes is higher than 9 5v you should add sea SALT NaCl to the water 25 50 kg depending on the size of the pool and volume of water Only at the starting and replenish if necessary After adding the salt the LEDs have to be fixed if flash is missing salt EXPLANATION To lower the voltage of Titanium electrodes either the water conductivity or the amount of Tot...

Page 31: ...heck the START UP option and decide the time required in order that the pool will be in optimal operating condition During that period pH will be regulated by the pH probe which will automatically send the information to Oxymatic Regulation takes place through the automatic injection produced from the peristaltic pump through real time probe readings It is essential that this process should be car...

Page 32: ...e software for the proper functioning of the system as well as to handle and maintain all the information of our system through our computer or our mobile phone system either Android or iPhone version Therefore we need to take the following steps Put he system in OFF mode 1 Press SET button and enter password 1122 2 Slide the display to find the WIFI option and press the button 3 Activate the WIFI...

Page 33: ...plug in connect OXYMATIC Smart 110 230V and return to the main screen The internet connection will now be working 9 2 OXYMATIC SOFTWARE UPDATE To update the software of our system you must have an active internet connection If you do not have please go back to the steps of the previous point and then continue to do the following 1 Go to main screen STATUS REPORT press the SET button and enter pass...

Page 34: ...Install button will be activated 5 Once activated press Install Update applications will appear Press YES button 6 Press Install button 7 Now the following screen will appear Press Decline button 8 This action will take you to the following screen where no action is required Once on this screen the computer will take you to the main screen STATUS REPORT and you will find your updated version Now t...

Page 35: ... effectively and to avoid deterioration they should work at only 9 5 v otherwise its life expectancy will be only a few months The GUARANTEE does not cover the deterioration of the electrodes The voltage should be measured weekly 10 2 Once the Oxymatic system is in progress If the pump circuit is turned on the PUMP light will go on PUMP ON If the OXY position is on the green light corresponding to...

Page 36: ... connected to the titanium electrodes are the cables that come out of the control unit if we are stood in front of it and the cables that lead to the copper electrodes are connected to the fifth or last port from the left The average frequency of cleaning depends on the water quality and quantity of flocculent used Visually check the electrodes every month and clean them when you see dirt between ...

Page 37: ...TATUS REPORT screen where we will get full information on the voltage and amps of our electrodes Voltage The voltage applied to the pair of electrodes is being checked The control unit applies a voltage of max 12 V This varies according to the electric conductivity in the water µS cm or the TDS Total Dissolved Solids ppm the higher the electric conductivity in the water the lower the voltage appli...

Page 38: ...OBRITE FILTERS It is very important not to use flocculants in the filter with zeobrite or just before filtering We recommend to add to the pool 12 SUMMARY OF MAINTENANCE OF THE OXYMATIC SMART SYSTEM 12 1 GENERAL Top up replace worn out products Never run short of products Replace electrodes when worn out approximately every 12000 15000 hours Change pH and Rx measurement probes when the calibration...

Page 39: ...olution 1 The first thing we need to do is to measure the copper in the water several times and at several locations If we find there is any copper we need to remedy this problem which may be attributable to Faulty installation Cables are transposed OXY ION Faulty programming too many minutes per day 2 Deprogram the copper function 3 Reduce the copper content in the pool This can be done in two wa...

Page 40: ...es 230 Vca peristaltic Residual Chlorine control No ON OFF free contacts Out Conductivity control No ON OFF free contacts Out Recirculating Pump out ON OFF Yes Yes Recirculating Pump out proportional Varioflow No 0 10 vcc PWM ECO Discaling Output No Yes by means PWM magnets ECO Discaling Chamber No PWM Swimming Pool Level Control No Up 3 levels detections Domotics Control Presence detector No Yes ...