Model Code
FAM 15-70 ATEX
en
Page 86 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
Model Code
Example:
FAM
- 50
- M - 2 - A - 45
- Z - Z
-
D - Z - 1 / -EX02-F
Product
FAM
= FluidAqua Mobil
Installation size
15
=
≈ 15 l/min
30
=
≈ 30 l/min
50
=
≈ 50 l/min
70
=
≈ 70 l/min
Operating fluid
M
= Mineral oil
– NBR seals, NBR houses,
checked with mineral oil*
B
= Biologically quickly biodegradable
(ester-based)
– FKM (FPM, Viton
®
)
seals, NBR hoses, checked with
biologically quickly biodegradable fluid
(ester-based)*
*Residues of test liquid will remain in the unit after
testing.
Mechanical type
1
= Stationary, with feet
2
= Mobile, with rollers) / wheels
Voltage/frequency/power supply
A
= 400 V (+/-10%), 50 Hz, 3 Ph+PE
B
= 415 V (+/-5%), 50 Hz, 3 Ph+PE
J
= 230 V (+/-10%), 50 Hz, 3 Ph+PE
Filter size fluid filter
15
= 1 x N15DM0xx (FAM-15)
30
= 2 x N15DM0xx (FAM-30)
45
= 3 x N15DM0xx (FAM-50)
60
= 4 x N15DM0xx (FAM-70)
Filter material
Z
= Without filter element
Filtration rating
Z
= Without filter element
Vacuum pump
D
= Rotary Vane Vacuum Pump
Instrumentation
Z
= Without
Modification number
You will always receive the current version
Supplementary details
EX02 = ATEX II 2G IIB+H2 T4 (+10°C<Ta<40°C, +10°C<TOil<60°C)
F
= Language version French