Technische Daten [Technical data]
Printed in the Federal Republic of Germany
HYDAC –ELECTRONICGMBH , All Rights Reserved
Stand:21.07.2010
Mat. Nr. 669792
Page 14 of 36
Environmental conditions
Vibration, DIN EN 60068-2-6: 1996.....................................
O
100 m/s², sine 50-2000 Hz
Shock, DIN EN 60068-2-27: 1995 ........................................
O
1000 m/s², half-sine 11 ms
EMV
- Transient emissions, DIN EN 61000-6-3: 2007
- Immunity to disturbance, DIN EN 61000-6-2: 2006
Operating temperature.......................................................... 0 °C…+70 °C, optional -20 °C…+70 °C
Storage temperature.............................................................. -30 °C…+85 °C, dry
Relative humidity, DIN EN 60068-3-4: 2002........................ 98 %, non condensing
Protection class, DIN EN 60529: 1991.................................
O
IP 65, dependent on the type of connector / connection
.................................................................................................... technology
Stray magnetic field, measured on the measuring level ........ < 3 mT
Pressure resistance, optional ................................................ 600 bar static
Mechanical characteristics
Measuring principle .............................................................. magnetostrictive
Measuring length, standard .................................................. 50 mm…2000 mm > 2000 mm on request, in steps of 50 mm
Resolution..............................................................................
O
0.005 mm
Linearity deviation, related to the measuring length ............ ± 0.1 mm up to 1.500 mm / ± 0.15 mm > 1.500 mm
Reproducibility......................................................................
O
0.005 mm
Hysteresis ..............................................................................
O
0.02 mm up to 1.500 mm /
O
0.1 mm > 1.500 mm
Temperature coefficient, related to the measuring length..... < 40 ppm/°C (Analog)
Temperature coefficient, related to the measuring length..... < 8
W
m/°C
O
500 mm / < 15 ppm/°C > 500 mm
Straight line velocity and mounting position......................... no restrictions
Material - measuring rod ...................................................... Cr/Ni - alloy
Rod end mounting ................................................................. Option