Step 3 - Mount Manifold and Connect Expansion Vessel 

• 

Orientation of the manifold is optional, but the direction of flow must follow the 

arrow on the manifold. The red handle is a service valve (boiling water isolation 

lever) for future maintenance.

• 

Position the boiling tank vertically beneath the tap so that the flexible hoses and 

tap connector (black lead, 3.5 mm jack) can comfortably reach the tap and water 

supply. 

• 

Choose desired location for manifold and mount using pipe clips (not supplied).

• 

Select a suitable location for the expansion vessel, consider the reach of hose 

labelled ‘manifold to exp vessel’ as well as the need to keep the vessel itself in an 

upright orientation (fitting at the bottom).

• 

Mount the expansion vessel bracket to the required surface using screw pack.

• 

Attach the other end of hose labelled ‘manifold to exp vessel’ to expansion vessel 

using 1 black washer.

• 

Secure expansion vessel in place against bracket using metal band.

Step 4 - Connect Boiling Tank and Life Tap

• 

Remove red caps from inlet and outlet connections at the back of the boiling tank.

• 

From offtake 2 of the manifold attach hose labelled ‘manifold to tank’ using 1 large 

white washer. Connect remaining end to tank inlet using 1 small white washer.

• 

Connect hose labelled ‘tank to tap’ to the tank outlet using 1 small white washer. 

Connect other end to threaded boiling tap connection using 1 small white washer.

• 

Connect the black lead tap connector which is attached to the tap to the back of 

the tank. This is a 3.5 mm jack which connects just above the tank inlet and outlet. 

11

Содержание Zen Life LIFE3L

Страница 1: ...Product Instruction Manual Zen Life Boiling Water Tap with Kitchen Hot Cold Mixer LIFE3L LIFE6L v20 1 1...

Страница 2: ...ttern recognition technology to learn and predict boiling water usage Supplied with initial scale filter for the inlet to the boiling tank Two temperature settings 100 C and 98 C Designed and assemble...

Страница 3: ...ef valve must be tested regularly to remove scale deposits see maintenance section Water may drip from the pressure relief valve this must be piped to drain as per local relevant regulations This appl...

Страница 4: ...anssion vessel Pressure relief valve Manifold Hose manifold to exp vessel Hose manifold to tank 1 5 m x 3 8 tubing fixing bracket and metal band Scale filter Hose tank to tap Zen tank Zen Life tap Exp...

Страница 5: ...2 x Black rubber washer 1 x Large and 3 x small white washer 4 x Large locking collar 4 x 1 2 BSP to 15mm 2 x 1 2 female to 3 8 PF 5...

Страница 6: ...is required if the mains pressure is above 0 42 MPa 4 2 bar The Zen Life is factory set at 100 C The temperature can be switched down to 98 C should this be desired Please see Section 6 for further in...

Страница 7: ...Diagram 1 Installation without Crossover Valve 7...

Страница 8: ...sink or worktop The required hole diameter is 32 mm fits in a standard sink The tap can be installed onto sink countertop up to 50 mm thick Place tap into hole ensure the black o ring is above the wo...

Страница 9: ...Diagram 2 9...

Страница 10: ...sover Valve please see Diagram 4 in Section 2 Note the boiling tank must be located as close to the tap as practicable as it is not possible to extend hoses provided Attach M BSP to 15 mm compression...

Страница 11: ...tting at the bottom Mount the expansion vessel bracket to the required surface using screw pack Attach the other end of hose labelled manifold to exp vessel to expansion vessel using 1 black washer Se...

Страница 12: ...n installation to secure Do not locate the filter above an electrical socket or other electrical device Step 5 Connect Mains Cold and Scale Filter The supplied scale filter is suitable for up to 300 p...

Страница 13: ...ngs supplied Replace the scale filter cartridge Without Crossover Valve Use a suitable length of 3 8 tubing cut using sharp knife ensuring a clean straight cut to connect from mains supply to scale fi...

Страница 14: ...able location to mount the Crossover Valve This may be the worktop near your tap or mount in your undersink kitchen cupboard if preferred Check that the position of the Crossover Valve is appropriate...

Страница 15: ...Diagram 4 Installation with Crossover Valve 15...

Страница 16: ...n for the drinking water filter housing ensuring easy access for future maintenance Do not locate the filter above an electrical socket or other electrical device Remove drinking water filter cartridg...

Страница 17: ...Diagram 6 Diagram 7 17...

Страница 18: ...t required to dispense standard hot and cold water If a Crossover Valve is installed check the valve switches between source A B mains cold and filtered cold This is identifiable as the flow rate thro...

Страница 19: ...x 13 minutes to heat up from cold depending on incoming water temperature Check for signs of discharge from the pressure relief valve IMPORTANT Following the first boiling cycle it is imperative to ch...

Страница 20: ...p and allow water to flow until the status ring flashes green The heater will then return to boiling shortly after If the status light begins flashing red this indicates a fault has been detected The...

Страница 21: ...factory setting is 100 C Please note the Zen tank is a storage type heater it cannot deliver a continuous flow of hot water Operating the Hot and Cold Mixer Tap For standard hot and cold mixed water...

Страница 22: ...removing by sliding it forward to free it from the retaining lug at the front For the 6L model unscrew the 2 crosshead screws that retain the back section and remove To change the temperature locate...

Страница 23: ...3L Model PC Board Diagram 8 6L Model PC Board Diagram 9 23...

Страница 24: ...warranty Regularly inspect the appliance for any signs of water leaks or damage If a leak or damage is discovered discontinue use isolate the water supply and drain down immediately Contact Hyco The r...

Страница 25: ...k turn upside down and drain all the water from the tank When re installing follow the original installation instructions 10 Descaling the Tank The tank should be descaled at least annually and more f...

Страница 26: ...rinking water filter cartridge See Section 8 Low flow from the boiling side of the tap Scale filter needs changing Replace scale filter cartridge See Section 8 Low flow from the boiling side of the ta...

Страница 27: ...retion supply a replacement product Incorrect installation frost damage the consequences of limescale deposits or failure to follow correct operating and maintenance instructions are excluded Conseque...

Страница 28: ...ing life this equipment must not be disposed of as household waste It must be taken to a local authority waste collection centre or to a dealer providing this service Disposing of electrical and elect...

Страница 29: ......

Отзывы: