8. TRoUBLe SHooTInG

If problems persist contact Hyco Technical dept on 01977 517555.

9. SpecIFIcATIonS

SyMpToM

poSSIBLe cAUSe

SoLUTIon

Water constantly flows 
from pressure relief valve

Water pressure is too 
high (above 4 bar).

Fit pressure Reducing 
Valve Kit (Hyco Kit SF4).

Water flows from 
pressure relief valve 
during heating cycle only

Heated water cannot 
expand back up inlet pipe 
due to obstruction.

Fit expansion Vessel Kit 
(Hyco kit SF3).

Water is not heated

1. Thermal cut-out has 

tripped.

1. See section 6. check 

heater is correct way 
up (pipes at top).

2. element has failed.

2. Replace element. See 

section 6 for access to 
element.

3. Thermostat has failed.

3. Replace thermostat.

Small volume of hot 
water

1. Unit upside down.

1. Re-install correct way 

up.

2. Thermostat set too 

low.

2. Increase thermostat 

setting.

3. Thermostat fault.

3. Replace thermostat.

Water appears to leak 
from heater

1. poor connections to 

pipework.

1. check plumbing 

connections, especially 
those to inlet and 
outlet.

2. element gasket leak.

2. refit gasket, tighten 

flange bolts evenly. Do 
not over tighten. See 
section 6 for access to 
element.

Supply

230V ~ 50Hz

power

2kW

Tank capacity

SF10K – 10 Litres
SF15K – 15 Litres

Tank Material

Vitreous enamel lined steel

dimensions  
(h x w x d)

SF10K  410 x 310 x 280 mm
SF15K  530 x 310 x 280 mm

pressure relief valve setting

6 bar

Thermal cutout

Manual reset

Содержание SF10K

Страница 1: ...Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2 0 May 2009...

Страница 2: ...P USE LOWEST ACCEPTABLE TEMPERATURE SETTING TO SAVE ENERGY AND REDUCE LIMESCALE DO NOT CONNECT TO POWER UNLESS UNIT IS FULL OF WATER OPEN TAP AND ALLOW WATER TO FLOW FREELY TO CLEAR AIRLOCKS DO NOT SW...

Страница 3: ...t interchangeable The final connection of the Speedflow to pipework should be implemented with flexible stainless steel hoses Open hot water tap and allow water to run through for at least 5 seconds t...

Страница 4: ...arthed IMPORTANT DO NOT SWITCH THE HEATER ON UNLESSYOU ARE CERTAIN THAT IT IS COMPLETELY FULL OF WATER FAILURE TO DO SO WILLVOID THE WARRANTY DIAGRAM B Cold draw off nearby DIAGRAM C Pressure above 4...

Страница 5: ...heating The thermal cut out may trip occasionally in normal use If this happens the heater will not heat water and the element light will not come on The thermal cut out is located underneath the uni...

Страница 6: ...artment on 01977 517555 To access the element or anode unscrew the bolts holding the flange in position The element and anode can then be removed Reverse to re fit 7 MAINTENANCE A grey cylindrical mag...

Страница 7: ...Replace element See section 6 for access to element 3 Thermostat has failed 3 Replace thermostat Small volume of hot water 1 Unit upside down 1 Re install correct way up 2 Thermostat set too low 2 In...

Страница 8: ...ND SERVICE POLICY This product is guaranteed against fault materials and manufacture for a period of one year from the date of purchase Hyco will in its sole discretion replace repair or refund any fa...

Отзывы: