background image

5

6. THermAl cUToUT reSeT, elemenT rePlAcemenT  
  And Anode RepLAceMenT (continued)

To reset the cutout, depress the button in the centre of the device. If the device 
has tripped reduce the thermostat setting if possible.

If the device trips repeatedly with a low thermostat setting, contact Hyco 
Technical department on 01977 517555.

To access the element or anode, unscrew the bolts holding the flange in position.

The element and anode can then be removed. reverse to re-fit.

7. MAInTenAnce

A grey cylindrical magnesium sacrificial anode is fitted to the element to aid 
tank corrosion resistance. The anode condition should be inspected annually and 
replaced if the there are signs of significant corrosion.
The pressure relief valve should be checked annually by twisting the cap and 
verifying water is discharged.

Содержание SF10K

Страница 1: ...Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2 0 May 2009...

Страница 2: ...P USE LOWEST ACCEPTABLE TEMPERATURE SETTING TO SAVE ENERGY AND REDUCE LIMESCALE DO NOT CONNECT TO POWER UNLESS UNIT IS FULL OF WATER OPEN TAP AND ALLOW WATER TO FLOW FREELY TO CLEAR AIRLOCKS DO NOT SW...

Страница 3: ...t interchangeable The final connection of the Speedflow to pipework should be implemented with flexible stainless steel hoses Open hot water tap and allow water to run through for at least 5 seconds t...

Страница 4: ...arthed IMPORTANT DO NOT SWITCH THE HEATER ON UNLESSYOU ARE CERTAIN THAT IT IS COMPLETELY FULL OF WATER FAILURE TO DO SO WILLVOID THE WARRANTY DIAGRAM B Cold draw off nearby DIAGRAM C Pressure above 4...

Страница 5: ...heating The thermal cut out may trip occasionally in normal use If this happens the heater will not heat water and the element light will not come on The thermal cut out is located underneath the uni...

Страница 6: ...artment on 01977 517555 To access the element or anode unscrew the bolts holding the flange in position The element and anode can then be removed Reverse to re fit 7 MAINTENANCE A grey cylindrical mag...

Страница 7: ...Replace element See section 6 for access to element 3 Thermostat has failed 3 Replace thermostat Small volume of hot water 1 Unit upside down 1 Re install correct way up 2 Thermostat set too low 2 In...

Страница 8: ...ND SERVICE POLICY This product is guaranteed against fault materials and manufacture for a period of one year from the date of purchase Hyco will in its sole discretion replace repair or refund any fa...

Отзывы: