background image

Hyco SpeedFLoW UnVenTed WATeR HeATeR
ModeLS SF10K (10 Litres) And SF15K (15 Litres)

1. InTRodUcTIon

Thank you for purchasing a Hyco Speedflow unvented water heater. This product
operates at mains water pressure and can supply hot water to two or more basins
using ordinary taps.

cAUTIon

 

THe SpeedFLoW MUST Be InSTALLed And MAInTAIned By  

 A coMpeTenT peRSon In AccoRdAnce WITH cURRenT  

 

eLecTRIcAL And pLUMBInG ReGULATIonS.

 

IT IS eSSenTIAL THAT THe encLoSed pReSSURe ReLIeF VALVe  

 IS FITTed

 

MAKe pLUMBInG connecTIonS WITH FLeXIBLe STAInLeSS  

 STeeL HoSeS To FAcILITATe FUTURe MAInTenAnce

 

ALWAyS FIT THe HeATeR THe coRRecT WAy Up  

 (pIpeS SHoULd Be AT THe Top)

 

USe LoWeST AccepTABLe TeMpeRATURe SeTTInG To SAVe  

 eneRGy And RedUce LIMeScALe

 

do noT connecT To poWeR UnLeSS UnIT IS FULL oF  

 WATeR – open TAp And ALLoW WATeR To FLoW FReeLy  

 

To cLeAR AIRLocKS

 

do noT SWITcH poWeR on IF WATeR In HeATeR oR pIpeS  

 coULd Be FRoZen

2. InSTALLATIon (WALL MoUnTInG)

The Speedflow is normally fitted immediately below the outlet to be supplied, but 
it can be mounted above or to the side of the outlet provided it is vertical with 
the pipe outlets at the top. The unit can either be placed directly on the floor or 
fixed to a wall using the mounting bracket supplied.

 

enSURe THe MoUnTInG SURFAce IS STRonG enoUGH To  

 SUppoRT THe SpeedFLoW IncLUdInG THe WeIGHT oF  

 

THe WATeR.

The 10 litre model (SF10K) can typically serve 1 or 2 sinks, and the 15 litre model 
(SF15K) can typically serve 2 or 3 depending on simultaneous usage.

1

Содержание SF10K

Страница 1: ...Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2 0 May 2009...

Страница 2: ...P USE LOWEST ACCEPTABLE TEMPERATURE SETTING TO SAVE ENERGY AND REDUCE LIMESCALE DO NOT CONNECT TO POWER UNLESS UNIT IS FULL OF WATER OPEN TAP AND ALLOW WATER TO FLOW FREELY TO CLEAR AIRLOCKS DO NOT SW...

Страница 3: ...t interchangeable The final connection of the Speedflow to pipework should be implemented with flexible stainless steel hoses Open hot water tap and allow water to run through for at least 5 seconds t...

Страница 4: ...arthed IMPORTANT DO NOT SWITCH THE HEATER ON UNLESSYOU ARE CERTAIN THAT IT IS COMPLETELY FULL OF WATER FAILURE TO DO SO WILLVOID THE WARRANTY DIAGRAM B Cold draw off nearby DIAGRAM C Pressure above 4...

Страница 5: ...heating The thermal cut out may trip occasionally in normal use If this happens the heater will not heat water and the element light will not come on The thermal cut out is located underneath the uni...

Страница 6: ...artment on 01977 517555 To access the element or anode unscrew the bolts holding the flange in position The element and anode can then be removed Reverse to re fit 7 MAINTENANCE A grey cylindrical mag...

Страница 7: ...Replace element See section 6 for access to element 3 Thermostat has failed 3 Replace thermostat Small volume of hot water 1 Unit upside down 1 Re install correct way up 2 Thermostat set too low 2 In...

Страница 8: ...ND SERVICE POLICY This product is guaranteed against fault materials and manufacture for a period of one year from the date of purchase Hyco will in its sole discretion replace repair or refund any fa...