Once the target temperature is set the heater will aim to reach it and will never
exceed it.
•
The heating performance of the heater is based on flow rates, the slower the flow
the higher the temperature uplift. The delivered temperature is the incoming water
temperature plus the temperature uplift (flow dependent).
•
A flow restrictor is supplied with this heater which, when fitted into the nozzle of a
tap will ensure a steady flow rate of 1.6 l/min is maintained. With this a temperature
uplift of 27°C is achieved.
•
The incoming water temperature can fluctuate dependent on time of year in the UK.
Winter may result in incoming temperatures below 10°C, whereas summer water
temperatures can be upwards of 15°C. It is imperative this is taken into account.
•
For example the heater could deliver 42°C water in the summer (with an incoming
water supply temperature of 15°C). The same product with the same flow rate would
only be able to deliver 37°C in winter (due to a lower incoming water temperature
of 10°C). The delivered temperature will be even lower if the incoming water supply
temperature is less than 10°C.
•
If there is a power interruption the heater will recall the last selected temperature.
When power is restored the heater must be turned back on using the bottom on/
off touch screen. Following this, it will again require 12 seconds (approximately) of
continuous water flow through the unit to start heating.
9