1. Installation
4
Choosing Heater Location
•
Consider the risks and consequences posed by any potential leak from the product or
supply pipework in the future. Avoid installation in areas where the consequences of
a leak could be unusually severe e.g. above computer equipment
•
Consider the potential for the pipework or heater freezing and take preventative
action if required e.g. pipe lagging.
•
It is advised that the heater be located as close as practical to the hot water outlet in
order to avoid unnecessary heat losses through the pipework and improve delivery
performance.
This heater should not be installed in a location where the risk of freezing cannot
be managed.
The heater is not suitable for use with thermostatic mixing valves or taps or to
supply a mixer tap.
Removing and Mounting the Bracket
•
Use a flat headed screwdriver or similar, place it into the lug on the bracket (between
the inlet/outlet connections, see diagram 1) and then gently lever the bracket away
from the heater.
•
To remove the bracket fully from the unit pull down at the bottom of the bracket.
•
When refitting the unit to the bracket reverse the process.
•
Before attaching the bracket to the wall, consider the wiring route to the heater. The
bracket on the heater has an additional knock out section to allow the wire to exit
from either the left, right or top of the bracket depending on wiring requirement.
Always ensure there are no hidden cables or pipes before commencement of
drilling.
Содержание Ara IN30T
Страница 1: ...Product Instruction Manual Ara Instantaneous Inline Water Heater IN30T v20 8 1...