- 27 -
Problems
Sources
Solutions
11. Unsmooth
chamfering
action.
a. Dull Blades.
b. The Tool Seats are not tightened.
c.
The Inside Tool Seat is larger than
the Work Piece Tube Inside
Diameter, and thus interferes
when chamfering.
a. Replace the Blades.
b. Tightened the Tool Seats.
c. While possible, grind or adjust
the shape of the Inside Tool
Seat for it to fit in the Tube,
and not interfere when
chamfering.
12. Improper
Adjustment of
the Tool Head.
a. Incorrect Results on the Facial
Chamfering.
b.
Incorrect results on the Inside and
Outside chamfering.
a. Adjust the Cutting Head
Moving distance for it to
properly perform the Facial
Chamfering.
b. Adjust the Inside and Outside
Tool Seats positioning.
13. Tube
Transferring
Angle Bar No
Action or
Non-Stop
Action.
a.
The Proximity Sensor on the Tube
Transferring Chain is not
functioning.
a. Test the Proximity Sensor.
Replace it when needed.