P/N 0520677_W
2-11
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Freedom Line Reach-in
INSTALLING PUMP & COLLECTION PAN KIT
Secure Pan Tubing
Plug Pan into GFCI Outlet
Condensate Pan
Tubing to Pump
Condensate Pan
(Installed on top of case)
Collection Pan & Pump Installed
(RFMN5)
Pump Assembly placed
on Floor under Case
Connect
½
” Tube from
Drain to the Pump
Factory-Installed Tee
Pump Discharge Line
Case Wire Whip
3.
(photo for reference)
4. & 5.
6.
3. Replace cover plates.
4. Connect tubing to pump.
5. Place pan and pump under case.
6. Connect tubing to condensate pan.
NOTE:
6A. 2 & 3-door medium temperature cases do not
have a condensate pan. Cases have a hose and
clamp that need to be field-installed and placed 2”
into condensing unit water outlet as shown below.
A
DETAIL A
2.00
INSERT 2" OF THE CONDENSATE
TUBE IN WATER PUMP HOSE AND
FASTEN BOTH WITH CLAMP HOSE
CLAMP HOSE 1/4" TO 5/8"
HOSE REINFORCED
CLAMP 3/8"
WASHER 1/4"
TUBE CU
WHEN INSTALLING MAKE SURE
THAT THE TUBE CU HAS THE
WATER OUTLET IN UNIT AS IT
SHOWN
6A
(only for 2 & 3-door medium temp. cases)