![Hussmann austral DD DELI-1 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/hussmann/austral-dd-deli-1-series/austral-dd-deli-1-series_installation-manual_2189204009.webp)
PRODUCT INSTALLATION MANUAL
DD13 2T SERVICE DELI
_________________________________________________________________________________________________________________________
Page 8
Hussmann
Cases must be positioned so that line-up numbers and case sequence numbers run in succession left to right standing in
front of the cabinet.
CAUTION
Ensure the lifting capacity of the trolley, etc. is
sufficient for the case. Refer to the product
engineering data tables and Risk Analysis (page 27).
To position the cases:
1. If the plinth surface is level, position the case designated as line up number 1 and case sequence number 1 in the
required position.
2. If the plinth surface is not level, determine where the highest point of the plinth is, and position the case allocated
to this position first.
3. Adjust the case height using the adjustable feet (if fitted) or metal shims (do
NOT
use
timber
) to ensure the case
is level to
/- 1.5mm
from front to back and side to side and chassis of case is
NOT twisted
. Maximum
25mm adjustment.
Fig (5) Levelling feet adjustment
NOTE
It is important that all cases are level for correct case joining and operation. If
cases are not properly levelled and positioned, door misalignment will be evident,
resulting in the job needing to be redone at complete cost to the installer
.
Hussmann is not liable or responsible for the cost involved in fixing
problems arising directly from the installers’ failure to follow the
requirements outlined in this manual.
DO
NOT
SET CASE LEVELS OFF THE PATCH END fitted to a case.