![Hussmann austral DD DELI-1 Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/hussmann/austral-dd-deli-1-series/austral-dd-deli-1-series_installation-manual_2189204026.webp)
PRODUCT INSTALLATION MANUAL
DD13 2T SERVICE DELI
_________________________________________________________________________________________________________________________
Page 25
Hussmann
1. Remove and clean the pan decks.
2. Remove any foreign material and food scrap from the base of the case.
3. Check drainage connections and clean the drain trap.
4. Check that all case panels, glass and trims are secure and undamaged.
5. Check for rust or paint damage.
6. Clean the air grilles on the cases.
7. Ensure all cable connections, including screw terminals, earth leads and straps, are secure.
8. Ensure insulation to all electrical components, including solenoid valves, fans, controls, earth terminals and lights,
are sound.
9. Carry out electrical safety tests, including earth continuity and insulation resistance.
10. Ensure that the correct fuse rating and type is fitted for all circuits.
11. Clean the evaporator coil and check it for damage.
12. Ensure that there are no refrigerant leaks.
With case power turned on:
13. Check that all fans, valves, lights and controls are working correctly.
14. Ensure light RCDs (if fitted) are working.
Operation Servicing
No servicing of Hussmann cases, is to be undertaken by store staff. Please contact your service contractor for all
maintenance queries.
NOTE:
Validate all electrical termination has been tightened once
more.
Check all electrical connections for tightness and re-tensioned
where needed prior to powering up the cabinet.