9 SHOCK ABSORBER, LINK FORK
ft
80
When the pressure gauge reaches the specified value, turn
control lever
Oil reservoir
0
to Vacuum.
Guideline
0 bar
✓ The vacuum gauge drops to the required value.
4 mbar
When the vacuum gauge reaches the required value, turn
control lever
Oil reservoir
0
to Equalize Pressure.
Guideline
14
mbar
✓ The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the specified value, turn
control lever
Damper
C,
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the required value.
3 bar
When the pressure gauge reaches the specified value, turn
control lever
Damper
C,
to Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the required value, acti
vate the
On/Off
switch.
Guideline
0 bar
✓ The vacuum pump is switched off.
Slide O-ring G) to the end of the special tool by the specified
value (distance
O
minus specified value).
Guideline
5mm
Depth micrometer (T107S) (
�
p. 320)
Slide the floating piston into the reservoir to the shortened
position using the special tool.