ELECTRICAL SYSTEM 15
91
Info
Even when there is no load on the 12-V battery, it discharges steadily each day.
The charging level and the method of charging are very important for the service life of the 12-V battery.
Rapid recharging with a high charging current shortens the service life of the battery.
If the charging current, charging voltage, or charging time is exceeded, electrolyte escapes through the
safety valves. This reduces the capacity of the 12-V battery.
If the 12-V battery is discharged by repeated starting, charge the 12-V battery immediately.
If the 12-V battery is left in a discharged state for an extended period, it will become deeply discharged
and sulfating occurs, destroying the battery.
The 12-V battery is maintenance-free. The acid level does not have to be checked.
Preparatory work
–
Remove the seat. (
F03808-10
Main work
–
Detach rubber strap
1
and take out tool set
2
.
–
Remove screws
3
.
–
Remove battery support bracket
4
.
F03807-11
–
Remove battery cover
5
from the 12-V battery.
–
Disconnect negative cable
6
from the 12 V battery to avoid
damaging the onboard electronics.
–
Pull back positive terminal cover
7
.