54 –
English
TECHNICAL DATA
Technical data
*Maximum pump flow and system pressure cannot be taken out at the same time, the motor will be overloaded. 60 Hz has limited
displacement.
Noise emissions
Noise emissions in the environment measured as sound power (L
WA
) in conformity with EC directive 2000/14/EC. The difference
between the guaranteed and the measured noise level is a measurement of dispersion and variations in the declared value.
Sound level
Reported data for sound pressure level has a typical statistical dispersion (standard deviation) of 2 dB(A).
* The stated value refers to work with a hydraulic hammer. Other types of recommended tools create a considerably lower noise
level.
General
Rotation speed, rpm
6
Transport speed max., km/h / mph
3/1,9
Angle of inclination, max.
30
°
Hydraulic system
Volume hydraulic system, l/gal
50/13
Pump type
Load sensing axial piston pump with variable displacement
Pump flow max.*, l/min / gal/min
65/17
Electric motor
Type
Siemens 1LE1001-1DB73
Power, kW
22 (50 Hz)
24,5 (60 Hz)
Speed, rpm
1475 (50 Hz)
1775 (60 Hz)
Voltage, V
380-420 (50 Hz)
440-480 (60 Hz)
Current, A
40,5 (50 Hz)
38,5 (60 Hz)
Control system
Control type
Remote control
Signal transmission
Bluetooth/cable
Weight
Without tools and hydraulic oil, kg/lb
1960/4320
Tools
Rec. max. weight, kg / lb
310/683
Machine without tool
Sound power level, measured dB (A)
87
Sound power level, guaranteed L
WA
dB (A)
94
Machine with tool (hydraulic hammer)
Sound power level, measured dB (A)
118
Sound power level, guaranteed L
WA
dB (A)
118
Sound level 10 m from the machine's tools*, dB(A)
90