English - 73
9. TROUBLESHOOTING
The robotic
lawnmower vibrates
Damaged blades lead to imbalance in
the cutting system.
Inspect the blades and screws and
replace them if necessary. See
8.7 Blades
on page 64.
Many blades in the same position
lead to imbalance in the cutting
system.
Check that only one blade is fitted at
each screw.
The robotic
lawnmower runs, but
the blade disc does
not rotate
The robotic lawnmower searches for
the charging station.
No action The blade disc does not
rotate when the robotic lawnmower is
searching for the charging station.
The robotic
lawnmower mows for
shorter periods than
usual between
charges
Grass or other foreign object blocks
the blade disc.
Remove and clean the blade disc.
See
8.4 Cleaning
on page 62.
Both the mowing and
charging times are
shorter than usual
The battery is spent.
Replace the battery. See
8.8 Battery
on page 65.
The robotic
lawnmower is parked
for hours in the
charging station
The robotic lawnmower must stand
for at least 8 hours per day in the
charging station in order to attain its
in-built standby, see
4.2 Using the
timer
on page 38.
No action
The cover has been closed without
the
START
button first being pressed.
Open the cover, press the START
button and then close the cover.
Symptoms
Cause
Action