AIR SUPPLY AND CONNECTIONS

The  connector  on  the  tool  must  not  hold 

pressure when air supply is disconnected.

Do  not  use  any  type  of  reactive  gases, 

including,  but  not  limited  to,  oxygen  and 
combustible gases, as a power source. 

Use  only a pressure-regulated  compressed 
air source to limit the air pressure supplied to 
the  tool. 

 If 

an incorrect fitting  is  used, the tool can remain 
charged with air after disconnecting and thus will 

be able to drive a fastener even after the air line 
is disconnected, possibly causing injury.

Use 

filtered,  lubricated,  regulated  compressed  air 

only.  Use  of  a  reactive  gas  instead  of 
compressed air may cause the tool to explode 
which will cause death or serious personal injury.

The  regulated  pressure  must  not 

exceed 100psi. If the regulator fails, the pressure 
delivered to the tool must not exceed 200psi. 

Always disconnect air source:

Before unloading or making adjustments.

When maintaining the tool.

When clearing a jam.

 When touching the safety yoke.

When tool is not in use.

When moving to a different work area.

    Such precautionary measures reduce the risk   
    of injury to persons.

LOADING TOOL

Do not load the tool with fasteners when any 

one of the operating controls is activated. 
Never  place  a  hand  or  any  part  of  body  in 
fastener discharge area of tool.

Never point tool at anyone.
Do  not  pull  the  trigger  or  depress  the 

workpiece  contact  as  accidental  actuation 
may occur, possibly causing injury.

The warnings and precautions discussed 

above  cannot  cover  all  possible 
conditions and situations that may occur. 
It  must  be understood  by  the user  that 

common  sense  and  caution  are  factors 
which cannot be built into this product, 

but must be supplied by the user.

WARNING:

!

UNPACKING 

This  tool  has  been  shipped  completely 

assembled.
Make sure that all items listed in the packing 
list are included.

Carefully  remove  the  tool  and  any 
accessories from the box.

Inspect  the  tool  carefully  to  make  sure  no 
breakage  or  damage  occurred  during 
shipping.

Do not discard the packing material until you 
have  carefully  inspected  and  satisfactorily 
operated the tool.

If any parts are damaged or missing, please 
call

.

 

1-866-676-8468

If  any  parts  are  missing  do  not  operate 

this  tool  until  the  missing  parts  are 
replaced. Failure to do so could result in 
possible serious personal injury.

WARNING:

!

Do not attempt to modify this tool or 

create  accessories  not  recommended 
for  use  with  this  tool.  Any  such 
alteration  or  modification  is  misuse 

and could result in hazardous condition 
leading  to  possible  serious  personal 

injury.

WARNING:

!

OPERATION

FEATURES

360 ADJUSTABLE  EXHAUST

COMFORT-GRIP HANDLE

ERGONOMICALLY ENGINEERED BODY

°

Allows user to direct air away from

.

For increased comfort and control.

 face

Rugged and Comfortable face resulting in a light-
weight tool great for extended use.

Safety for users.

Eliminates damage to working surface.

DUAL TRIGGER

NON-MARRING SAFETY CONTACT

FEATURES

SPECIFICATIONS

REQUIRES: 

 

AIR INLET: 
MAGAZINE CAPACITY:

WEIGHT: 
MAXIMUM PRESSURE: 
PRESSURE RANGE: 

1.36 SCFM with 100

fasteners per minute @ 80psi

1/4 inch NPT

2.24 lbs

100psi

60psi   100psi

100 headless pins, 23 gauge

 1/2 inch to 1 inch

PIN SIZE RANGE:

ADJUSTING THE EXHAUST

The adjustable exhaust on the cap of the tool allows 

users  to  direct  the  exhaust  according  to  operator 
preference. To adjust the direction, turn the exhaust 
cap in the desired direction. 

Compatible with All Brands 23 Gauge Micro Pins.

5/8

16mm

12mm

19mm

22mm

25mm

3/4

7/8

1

   1 /2

 

LOADING FASTENERS

Connect the tool to the air source.
Set the pin length  adjustment switch( ) to the 

appropriate setting for the length of pins you are 
loading  by  first  pushing  in  on  the  orange 
switch( )  and  sliding  until  the  notch  is  in  the 

appropriate groove.

A

A


Push  the  latch  button(B).  Pull  back  on  the 

magazine cover fully(C).

Latch 
button(B)

Length adjustment switch(A)

Respect the tool as a working implement.

Never engage in horseplay.
Never pull the trigger unless nose is directed         
toward the work.

Keep others a safe distance from the tool        
while tool is in operation as accidental       
actuation may occur, possibly causing injury.

Содержание DPP123

Страница 1: ...iados No devuelva la herramienta neumática a la tienda Esté preparado para enviar el producto franqueo prepagado junto con una copia del recibo de compra con la fecha en la que se adquirió el producto y el modelo de la herramienta a PRIME GLOBAL PRODUCTS INC Dirección Ball Ground Ga 30107 Un producto defectuoso será reemplazado con uno nuevo de igual o mayor valor Esta garantía excluye daños accid...

Страница 2: ... moment of inattention while operating the tool may cause serious injury Keep fingers away from trigger when not driving fasteners especially when connecting the tool to the air supply Remove finger from the trigger when not driving fasteners Always wear eye protection Always wear hearing protection when using the tool Never carry the tool with finger on trigger the tool is able to fire a fastener...

Страница 3: ...for use with this tool Keep the tool and its handle dry clean and free from oil and grease Do not use the tool as a hammer Never use this tool in a manner that could cause a fastener to be directed toward anything other than the workpiece Never use gasoline or other flammable liquids to clean the tool Do not remove tamper with or otherwise cause the trigger lock or trigger to become inoperable Fas...

Страница 4: ...eakage or damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operated the tool If any parts are damaged or missing please call 1 866 676 8468 If any parts are missing do not operate this tool until the missing parts are replaced Failure to do so could result in possible serious personal injury WARNING Do not attempt to modify t...

Страница 5: ...e the tool into scrap wood repeatedly to make sure all of the compressed air is expended WARNING SETTING THE AIR PRESSURE The amount of air pressure required depends on the size of the fasteners and the workpiece material Begin testing the depth of drive by driving a test nail into the same type of workpiece material used for the actual job Drive a test fastener with the air pressure set at 90 95p...

Страница 6: ... pressure from the power source if a regulator fails or 150psi whichever is greater Use 3 8 air hose for runs up to 50 Use 1 2 air hoses for 50 run or longer For better performance install a 3 8 quick plug 1 4 NPT thread with an inside diameter of 0 315 8mm on the tool and 3 8 quick coupler on the air hose Use a pressure regulator on the compressor with an operating pressure of 0 125psi A pressure...

Страница 7: ...LE CAUSE S CORRECTIVE ACTION 1 Lubricate nailer 2 Replace spring 3 Replace damaged internal parts 1 Tool not lubricated sufficiently 2 Broken spring in cylinder cap 3 Exhaust port in cap is blocked Tool runs slow or has loss of power 1 Replace guide 2 Use only recommended fasteners 3 Replace with undamaged fasteners 4 Tighten screws 5 Replace driver 1 Guide on driver is worn 2 Fasteners are not co...

Страница 8: ...123 ADVERTENCIA No seguir las advertencias correctamente puede causar LA MUERTE O LESIONES GRAVES GUARDA ESTE MANUAL PARA CONSULTARLO EN EL FUTURO GUARDE SUCOMPROBANTE DE COMPRA CON FECHA PARA FINES DE LA GARAT A Í ...

Страница 9: ... áreas oscuras aumentan el riesgo de La herramienta produce una chispa que podría encender líquidos inflamables gases o polvo accidentes Mantenga a los transeúntes niños y a otras personas alejadas cuando esté utilizando la herramienta Las distracciones podrían resultar en el uso inapropiado y causar lesiones SEGURIDAD PERSONAL Evite los disparos accidentales Siempre tenga precaución para evitar d...

Страница 10: ...rdes filosos Siempre dé por sentado que la herramienta contiene sujetadores Siempre mantenga a las demás personas a una distancia segura del lugar de trabajo en caso se produzcan descargas accidentales de sujetadores No deje caer ni lance la herramienta Evite usar la herramienta cuando el cargador está vacío Limpie y revise todas las mangueras y conectores de suministro de aire comprimido antes de...

Страница 11: ...bricante para ese modelo específico de herramienta la utilización de pi eza s no au t or iza das o e l incumplimiento de las instrucciones de mantenimiento pueden aumentar el riesgo de lesiones Usa únicamente los lubricantes provistos con la herramienta o especificados por el fabricante La reparación de la herramienta debe ser realizada únicamente por personal calificado Al mantener una herramient...

Страница 12: ...AR SUJETADORES ATASCADOS En ocasiones un sujetador puede atascarse en el mecanismo de disparo dejando la herramienta inoperante Para retirar el sujetador atascado siga los siguientes pasos CARACTERÍSTICAS OPERACIÓN Conecte la herramienta a la fuente de aire Configure el interruptor de ajuste de longitud del clavo A a la longitud adecuada de los clavos que está cargando presionando primero el inter...

Страница 13: ...través de la conexión de la línea de aire se lubricarán las piezas internas No utilices aceite detergente ni aditivos puesto que estos lubricantes causarán el desgaste acelerado de los sellos y amortiguadores de la herramienta lo que resultará en el mal funcionamiento de la misma y elevará la frecuencia del mantenimiento LUBRICACIÓN Desconecta la herramienta de la fuente de aire a agregue lubrican...

Страница 14: ...ma podría dejar de funcionar PRECAUCIÓN Compresor El compresor de aire debe ser capaz de mantener un mínimo de 4 14bar mientras la herramienta está en uso Un suministro inadecuado de aire puede causar una pérdida de potencia y un clavado desigual Acople rápido Manguera de aire Lubricador Filtro Conector rápido Regulador Conector rápido Acople rápido Deje de utilizar inmediatamente la herramienta s...

Отзывы: