BALANCING PROCEDURES 39
INNER
DATASET
ARM
Figure 148.
If the Split Spoke® feature of hiding weights behind
spokes is to be used, position the Dataset® arm disk in
the center of a spoke and tap the foot pedal.
Figure 149.
Move to the next spoke and repeat. Up to 10 spoke
locations may be entered.
Close safety hood.
Touch the green “START” button if “Hood Autostart” is
disabled.
As the wheel is spinning, the amount(s) of corrective
weight(s) needed will be shown on the screen. This time
can be used to find and prepare the needed weights.
Once weight amounts are shown on the screen,
they can be toggled to display either ounces or
grams by pressing the “oz” or “g” graphic shown
after the weight amount.
Figure 150.
After wheel comes to a complete stop, raise safety hood.
If Auto Hood is enabled, the hood will raise
automatically.
Verify that the wheel is clean and free of debris.
Remove all previous weights.
Mount tire/wheel assembly.
Use the inner Dataset® arm in the UPWARD position
at the clip-on weight location to measure the distance,
diameter, and rim width dimensions.
Figure 145.
INNER
DATASET
ARM
Figure 146.
Do NOT return the arm to the “home” position.
Using the DOWNWARD position, move the inner
Dataset® arm disk edge to the location for placement of
the right edge of the adhesive weight on the right weight
plane and enter data by depressing the foot pedal.
Figure 147.