GENESIS OPERATIONS MANUAL
38
DISPLAY MESSAGES
Cold Start!
1. Someone performed an Erase
Program sequence.
2. Battery failure.
1. Press CLEAR to remove message
from display.
2. Return the facepack to the factory
or the nearest authorized Service
Center.
Overload! #nn
1. Solenoid failure at valve nn.
2. Programming error caused too many
valves to come on (more than 3
Amps).
3. Wiring to valve is damaged.
1. Replace solenoid at valve nn.
2. Review all Programs and Starts
for overlaps.
3. Perform ground fault check on
valve wiring and repair or replace
if necessary.
Power Outage!
1. Power to the field controller has
been interrupted.
1. Press CLEAR to remove message
from display.
Fuse Open!
1. Fuse has blown.
1. Check all valve wiring and
solenoids for short to ground and
replace fuse. (Message will
disappear once a good fuse is put
into place.)