GENESIS OPERATIONS MANUAL
31
MAINTENANCE RADIO COMMAND DEFINITIONS
(# = on
= off )
Command
Definition
*aaa#nnn#
This addresses Field Controller # aaa and turns on the station number entered as
nnn . A single acknowledgement tone will sound on the hand-held if successful.
*aaa#nnn# (continued)
Station nnn will be activated for the default time set up in the field controller in the
global options, MR runtime. After that time the valve nnn will automatically be shut
off by the FC.
*aaa#nnn*
Manually turns station nnn off regardless of the time remaining.
*aaa#970#ttt#
Sets up a timed syringe cycle for all currently active stations in Hours:Minutes mode.
All of the stations will remain on simultaneously for ttt Hours:Minutes (e.g. If you
enter the command 970#110#, all active stations will remain on for 1 hour and 10
minutes). After the command has been sent to the FC, you will get a single
acknowledge tone if it was successful.
*aaa#970#ttt*
Sets up timed syringe cycle for all currently active stations in Minutes:Seconds mode.
All of the stations will remain on simultaneously for ttt Minutes:Seconds (e.g. If you
enter the command 970#110*, all active stations will remain on for 1 minute and 10
seconds). After the command has been sent to the FC, you will get a single
acknowledge tone if it was successful.
*aaa#97p#s##
Program p start s will be started semi-automatically beginning with station #1. When
the semi-auto sequence is finished, the FC will return to normal operation.
*aaa#97p#s#nn#
Program p start s will be started semi-automatically beginning with station #nnn.
When the semi-auto sequence is finished, the FC will return to normal operation.
*aaa#976*
This command stops all irrigation at the FC aaa.
*aaa#992#
Enables the sequential station operation function. Once the command is entered you
are able to step-up or step-down one station at a time from the station that was active
before the command was issued.
NOTE: IF more than one station was active when the 992# command was sent, only the first station turned on will
remain active and be capable of being stepped up or down. If no stations were active, station #1 will be started.
The active valve will remain active for the amount of time selected in the MR runtime options. A single acknowledge
tone will be returned if the command was received by the field controller.
*aaa ##
Once the 992# command has been accepted, entering *aaa## on the hand-held will step-up the
active station to the next highest station. (e.g.: If station #3 was active, it will shut off and station #4
will be turned on for the default Run Time). If the current station happens to be the highest number
station in the controller, station #1 will be activated.
*aaa# *
Once the 992# command has been accepted, entering a *aaa #*on the hand-held will step-down
the active station to the next lowest station. (e.g.: If station #3 was active, it will shut off and station
Содержание Genesis