GENESIS OPERATIONS MANUAL
28
Completes the removal of Programs from memory. The display shows:
Cold Start!
This message shows in the display, alternating with the time in hours and minutes.
If the default Program is loaded by Option 12, Cold Start returns all programming to the default setting: Ten
minutes Run Time per station, at 10 PM every day, for Program 1, Start 1 only.
Press CLEAR to remove the Cold Start message. The display shows the time in hours, minutes, and
seconds.
Maintenance Radio Operations
NOTE: This section pertains to radio-equipped Genesis series controllers only. If your controller is hard-wired and
uses Maintenance Radio through the central interface (at the computer), please refer to the manual for your central
interface for maintenance radio instructions.
Genesis Maintenance Radio is a valuable tool that allows remote control of your irrigation controller by means of a
UHF hand-held transceiver- directly to any Genesis Radio series controller.
With the Genesis Maintenance Radio, you can:
Manually control any valve of any Field Controller (FC) in your system.
Semi-Auto start a Program/start of any FC, even on a particular station
Perform timed syringe cycles on up to six valves simultaneously in either HH:MM or MM:SS mode.
Sequentially step-up/step-down valves on a Field Controller.
All Genesis Radio field controllers have the ability to respond directly to a UHF handheld radio transceiver (on the
correct frequency) equipped with a DTMF (dual tone, multi-frequency, or TouchTone ) key pad.
Genesis Radio controllers do NOT require the central computer system to communicate with Maintenance Radio
transceivers.