background image

 

To select a unit of measurement, press the SELECT button until the box before UNITS is blacked 

in. Then, press the Up or Down arrow to select the unit to change. Press ON-OFF until the unit you want is 
displayed. 
 
 

To adjust the contrast of the Dimension 3 display, press the SELECT button until the box before 

CONTRAST is blacked in. Then, press the Up or Down arrow until the screen shows the desired degree of 
contrast. 
 
 

When you are finished with t he Custom Program screen, press the SCREEN key to return to 

normal Dimension 3 operation. 

Содержание Piranha 3

Страница 1: ......

Страница 2: ...uding aluminum Please carefully consider the following before installing your transducer TRANSDUCER MOUNTING OPTIONS A Transom Mount The Humminbird high speed transducer allows the transducer element...

Страница 3: ...bronz thru hull transducer has a threaded stem which installs through a hole drilled in the boat hull leaving the housing exposed under the boat This type of installation must be used for many boats...

Страница 4: ...use a silicone sealant between the screwhead and bracket in order to prevent leaking See Figure C Step 2 BRACKET INSTALLATION Fiberglass Boats If your boat has a stepped transom located below and und...

Страница 5: ...cally in the three slots found in the bracket It is important to use a silicone sealant between the screwhead and bracket in order to prevent leaking Step 3 TRANSDUCER PIVOT ASSEMBLY Assemble the pivo...

Страница 6: ...the bracket Slide the O ring on to the headed pin and insert it through the two parts Assemble by screwing the x3 8 allen head screw into the end of the pin and tighten See Figure G Step 5 ANGLE ALLIG...

Страница 7: ...h this type installation it is important that the transducer be mounted by someone familiar with the use of two part epoxy adhesives For this reason Techsonic Industries Inc will not be responsible fo...

Страница 8: ...ye of the transducer The bubbles will disappear in a short time or can be removed by rubbing the transducer eye with your fingers while the transducer is in the water 4 If your instrument should fail...

Страница 9: ...Install the mounting knobs and tighten snugly The unit can now be swiveled and tilted to any desired position...

Страница 10: ...cket can also be mounted directly to the dash without the swivel mount however this method is not recommended since the unit cannot be rotated INSTALLING THE CABLES Your LCR comes equipped with Hummin...

Страница 11: ...ole cover after determining the necessary wire length from the hole The power cable has a red lead to the positive post and the black lead to the negative post Install a 1 amp fuse between the red cab...

Страница 12: ...l mount aside and drill the holes as marked 5 Mount the bracket using the mounting hardware supplied with your Dimension 3 Note Twist the bracket 90 degrees on the swivel base to access the mounting s...

Страница 13: ...ater images on the Dimension 3 screen You should read this section and Section S Selecting Dimension 3 Functions as you first learn to use the Dimension 3 Doing so will ensure you make the most of its...

Страница 14: ...utton controls the 2 position backlight Press LIGHT once to turn the backlight on dim pressing a second time will turn the backlight to bright Pressing a third time will turn the light off In either a...

Страница 15: ...verse angle as shown below is as if you were forward and to the right of your boat looking back on the area you have covered Normal view is the reverse of this so objects to the right of your boat app...

Страница 16: ...Screen with Reverse Angle activated shows the bottom that would normally be blocked...

Страница 17: ...he SCREEN button once displays a front view much like using a rearview mirror Press it a second time for a side view like conventional 2dimensional sonar products display Press it again to return to t...

Страница 18: ...d off by simply pressing ON OFF The menu Select System works in all three views although the following descriptions arc illustrated in the 3 4 view unless there are significant differences in operatio...

Страница 19: ...he depth you have set DEPTH LIMIT MESSAGE As the bottom depth approaches the depth limit 240 a depth limit message appears in front and 3 4 views or when a menu item such as zoom or depth range is adj...

Страница 20: ...ted for depth so shallow fish don t appear linger than deeper fish 5 Using Zoom Factory setting OFF Zoom provides an up close view To activate it select ZOOM Press the Up and Down arrows to move the Z...

Страница 21: ...and the same view after zoom is activated Vertical bars also indicate zoomarea in the straight on view Horizontal lines indicate zoom area in the side view...

Страница 22: ...rter vertical bar To use this feature select BOTTOM HARDNESS and press ON OFF NOTE Bottom Hardness is factory set for average bottom hardness You can adjust the scale so a known bottom will read as ha...

Страница 23: ...hour or knots and whether temperatures are displayed in fahrenheit or centigrade 3 You can adjust screen contrast to optimize viewability for your mounting location To do any of these press the SCREE...

Страница 24: ...ON OFF until the unit you want is displayed To adjust the contrast of the Dimension 3 display press the SELECT button until the box before CONTRAST is blacked in Then press the Up or Down arrow until...

Отзывы: