![Humidity Source ElectroVap RTH Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/humidity-source/electrovap-rth/electrovap-rth_installation-manual_2183712027.webp)
ElectroVap RTH
Tank Maintenance
Maintenance
25
Drain the tank by pressing the manual
drain button (Picture 1). Wait for complete
draining and allow the tank to cool down (in
case this feature has been enabled)
Cut off the power supply at the disconnect
switch and switch off the RTH humidifier
Screw off the front door, lift it a little and
take it away. Remove the black steam
hose from the steam tank (Picture 2) and
draw it out of the humidifier.
Loosen the black tank release knob and
remove the drain hose (Picture 3).
Swing the tank to intermediate position
(Picture 4).
Unlock the 4 locks of the tank (Picture 5).
Take off the water level tank cap (Picture 6).
CAUTION : do not use any solvent to clean
the water level tank. If the sensor needs
being attended, use teflon material only.
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
Picture 6