D.C. tachometer generator TDP 0,7
22
BETR-TDP0,7-en_R5(2018-12-20)ID74716 .doc
commutator contact face) as
a result of the air being too
dry.
avoid dust in ambient air).
Brush pressure too high
Contact the manufacturer.
Grease on brush contact face
Clean contact face (contact
the manufacturer)
Heavy vibration
* See above.
Surface temperature too high
(>100 °C)
Operated under short-circuit
conditions
Check device; please
contact the manufacturer.
Other faults
Please contact the
manufacturer.
6.2
Inspection and maintenance schedule
PLEASE NOTE!
No other actions are required to be carried out
on the device in addition to the following
cyclical inspections described in this inspection
schedule. Any attempt to tamper with the
device will result in the warranty being declared
null and void!
Caution! Replace the sealing ring on special versions (tacho-generators with speed increasing gear)
after 5000 to 8000 hours of operation. Blow out metal filter of tacho-generators designed with
ventilation vents (IP 55 spec.).
Contact the manufacturer when operating any other special version and combinations of devices (e.g.
TDP 0.7 + FSE 102).
Interval
Inspections
To be carried out by
Regularly
Check fastening screws are seated
correctly
Skilled personnel
After approx. 2000 operating
hours
Check carbon brushes; blow carbon
brush dust out of the machine using dry,
oil-free compressed air; check ease of
movement. When changing carbon
brushes (service life approx. 10 000 –
20 000 operating hours depending on
environmental conditions and speed)
ensure the new brushes are of the same
quality and type. Please note: Double
tacho-generators have 2 commutators
and 2 brush rockers).
Skilled personnel
After approx. 2000 operating
Clean soiled commutators using a clean, Skilled personnel
Содержание TDP 0,7 Series
Страница 25: ...D C tachometer generator TDP 0 7 25 BETR TDP0 7 en_R5 2018 12 20 ID74716 doc 10 Dimension drawings...
Страница 26: ...D C tachometer generator TDP 0 7 26 BETR TDP0 7 en_R5 2018 12 20 ID74716 doc...
Страница 27: ...D C tachometer generator TDP 0 7 27 BETR TDP0 7 en_R5 2018 12 20 ID74716 doc...
Страница 28: ...D C tachometer generator TDP 0 7 28 BETR TDP0 7 en_R5 2018 12 20 ID74716 doc...
Страница 29: ...D C tachometer generator TDP 0 7 29 BETR TDP0 7 en_R5 2018 12 20 ID74716 doc...
Страница 30: ...D C tachometer generator TDP 0 7 30 BETR TDP0 7 en_R5 2018 12 20 ID74716 doc...