Hubner FGH 8 Скачать руководство пользователя страница 6

Incremental hollow shaft encoder FGH 8 

 

 

 

 

FGH8_MANUAL-en_R6(2018-11-19)ID74584.docx

 

 

1.4

 

Disclaimer 

All information and instructions in these Operating and Assembly Instructions have been provided under 
due consideration of applicable guidelines, as well as our many years of experience. 
The manufacturer assumes no liability for damages due to: 

 

Failure to follow the instructions in the operating and assembly instructions 

 

Non-intended use 

 

Deployment of untrained personnel 

 

Opening of the device or conversions of the device 

In all other aspects the obligations agreed in the delivery contract as well as the delivery conditions of 
the manufacturer apply. 
 

1.5

 

Copyright 

 

NOTES! 

Content information, text, drawings, graphics, and other representations are protected 
by copyright and are subject to commercial property rights. 
It is strictly forbidden to make copies of any kind or by any means for any purpose other 
than  in  conjunction  with  using  the  device  without  the  prior  written  agreement  of  the 
manufacturer. Any copyright infringements will be prosecuted. 

 

1.6

 

Guarantee terms 

The guarantee terms are provided in the manufacturer’s terms and conditions. 

1.7

 

Customer service 

For technical information personnel is available that can be contacted by telephone, fax or email.  
See manufacturer’s address on page 2. 

2

 

Safety 

 

DANGER! 

This  section  provides  an  overview  of  all  the  important  safety  aspects  that  ensure 
protection of personnel, as well as safe and trouble-free device operation. 
If these safety instructions are not complied with significant hazard can occur. 

2.1

 

Responsibility of the owner 

The device is used in commercial applications. Consequently the owner of the device is subject to the 
legal occupational safety obligations and subject to the safety, accident prevention and environmental 
protection regulations that are applicable for the device’s area of implementation. 

2.2

 

Intended use 

The device has been designed and constructed exclusively for the intended use described here. 
Series FGH 8 Incremental hollow shaft encoder are used for measurement of rotations, for instance of 
electrical and mechanical drives and shafts. 
Claims of any type due to damage arising from non-intended use are excluded; the owner bears sole 
responsibility for non-intended use. 
 

 

Содержание FGH 8

Страница 1: ...structions FGH8_MANUAL en_R6 2018 11 19 ID74584 docx ID 74584 Operating and Assembly Instructions Incremental hollow shaft encoder FGH 8 Read the operating and assembly instructions prior to assembly...

Страница 2: ...one 49 641 7969 0 Fax 49 641 73645 E Mail info huebner giessen com www huebner giessen com Headquarters Giessen Court of registration Giessen Commercial register number HRB 126 The manual has been dra...

Страница 3: ...8 2 6 2 Rotating shafts Hot surfaces 8 2 6 3 Safeguarding against restart 8 3 Technical Data 9 3 1 Type plate 9 3 2 Electrical and mechanical data 9 3 3 Type code 12 4 Transport packaging and storage...

Страница 4: ...GH 8 4 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx 8 Inspections 19 8 1 Safety instructions 19 8 2 Maintenance information 19 8 3 Inspection schedule 19 9 Disposal 20 9 1 Disposal procedure 20 10 Dimens...

Страница 5: ...e hazard The warnings must be strictly heeded you must act prudently to prevent accidents personal injury and property damage WARNING Indicates a possibly dangerous situation that can result in death...

Страница 6: ...will be prosecuted 1 6 Guarantee terms The guarantee terms are provided in the manufacturer s terms and conditions 1 7 Customer service For technical information personnel is available that can be co...

Страница 7: ...o the device for example a crane hook to lift a motor Fastening packaging components to the device for example ratchet straps tarpaulins etc Using the device as a step for example by people to climb o...

Страница 8: ...t surfaces WARNING Danger of injury due to rotating shafts and hot surfaces Touching rotating shafts can cause serious injuries Therefore Do not reach into moving parts shafts or handle moving parts s...

Страница 9: ...rical and mechanical data Pulse rates Value Preferred Pulse Rates 1024 2800 4096 Special pulse rates 600 720 750 1000 1200 2048 2560 Connection data Supply voltage 12 V to 30 V DC option 5 V DC Ripple...

Страница 10: ...eed and degree of protection of the device Protection class acc to DIN EN 60529 Sealing Mechanical speed Description Breakaway torque IP 54 Special seal 3000 rpm Protection against dust and water spra...

Страница 11: ...or 4 times as many pulses as the basic version No direction of motion can be derived from the multiple number of pulses Required Option 90 Option B Fast and precise sensing of rotational direction at...

Страница 12: ...strial plug ER EER 12 pole round plug EC EEC 2 m connection cable Pulses per revolution Basic signal output Basic channel 0 A Pulse channel 90 B Each with inverted signals NG Option reference pulse wi...

Страница 13: ...he goods about existing transport damages prepare pictures for evidence 4 3 Packaging disposal The packaging is not taken back and must be disposed of in accordance with the respective statutory regul...

Страница 14: ...ed warranty void 5 2 1 Mounting Instruction for hollow shaft encoder 1 Adapter flange has to be mounted and to be aligned by dial gauge if necessary optimize by ball thrust adjusting screws 2 Ball thr...

Страница 15: ...d CAUTION Danger of damage to shaft and device if improperly handled Ensure that there are no hard impacts on hollow shaft and housing Use the mounting sleeve 7 Fasten axial tensioning elements Screw...

Страница 16: ...ion cable Wiring arrangement and shielding EMI measurement The cable shielding must be placed on both sides The shield of the signal cable has to be connected directly to the housing of the encoder by...

Страница 17: ...hapter 3 2 Degree of protection To fulfill degree of protection requirements the diameter of the connection cable must correspond to that of the cable gland Please refer to Chapter 5 3 1 6 Dismantling...

Страница 18: ...signals Supply voltage not connected Connect supply voltage Connection cable reversed Wire correctly Output signals subject to interference Unsuitable cable Use data cable with conductors arranged as...

Страница 19: ...ce free However to guarantee optimum fault free operations we recommend that you carry out the following inspections 8 3 Inspection schedule Interval Inspections Tasks All 12 month Check coupling Qual...

Страница 20: ...he manufacturer is not obliged to take back the device The device is classed as electronic equipment and subject to the WEEE Directive observe local country specific laws when disposing of the device...

Страница 21: ...Incremental hollow shaft encoder FGH 8 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx 21 10 Dimension drawings...

Страница 22: ...Incremental hollow shaft encoder FGH 8 22 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx...

Страница 23: ...Incremental hollow shaft encoder FGH 8 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx 23...

Страница 24: ...Incremental hollow shaft encoder FGH 8 24 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx...

Страница 25: ...Incremental hollow shaft encoder FGH 8 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx 25...

Страница 26: ...Incremental hollow shaft encoder FGH 8 26 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx...

Страница 27: ...Incremental hollow shaft encoder FGH 8 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx 27...

Страница 28: ...Incremental hollow shaft encoder FGH 8 28 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx 11 Connections FGH 8 standard terminal box FGH 8 standard connection cable...

Страница 29: ...Incremental hollow shaft encoder FGH 8 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx 29 FGH 8 standard 12 pole round plug FGH 8 standard 15 pole industrial plug...

Страница 30: ...Incremental hollow shaft encoder FGH 8 30 FGH8_MANUAL en_R6 2018 11 19 ID74584 docx FGH 8 standard 42 pole industrial plug...

Отзывы: