Incremental Hollow Shaft Encoder FGH 40
34
FGH40_MANUAL-en_R10(2018-10-31)ID74492.doc
12 pole printed circuit spring terminal block type
Phoenix ZFKDS
Connection data:
Wire section
0,2-1,5 [ mm² ]
Shielding:
The shield of the signal cable can be connected
directly to the housing of the encoder by the
cable gland. Alternatively the shield of the cable
can be connected to K13 via a capacitor (10nF /
500V) to the housing of the encoder.
Alternative Shielding
FGH 40
Option F2
Terminal box
10 pole printed circuit spring terminal block
type Phoenix ZFKDS
Connection data:
Wire section
0,2-1,5 [ mm² ]
Shielding:
The shield of the signal cable can be connected
directly to the housing of the encoder by the
cable gland. Alternatively the shield of the cable
can be connected to K13 via a capacitor (10nF /
500V) to the housing of the encoder.
Alternative Shielding
FGH 40
Option B
Terminal box