Incremental Hollow Shaft Encoder FGH 40
24
FGH40_MANUAL-en_R10(2018-10-31)ID74492.doc
7
Inspections
7.1
Safety instructions
WARNING!
Skilled technical staff only are permitted to inspect the device and its installation.
Observe the safety instructions contained in Chapter 2 when inspecting or working on
the device!
7.2
Maintenance information
The device is maintenance-free. However, to guarantee optimum fault-free operations we recommend
that you carry out the following inspections.
7.3
Inspection schedule
Interval
Inspections
Yearly
Ensure the fastening screws are properly tightened
Ensure cable connections and connection terminals are
securely seated
Following approx 16 000 … 20 000
hours of operation / higher levels of
continuous load
Check deep groove ball bearings are running smoothly and
listen for running noises
8
Disposal
8.1
Disposal procedure
The manufacturer is not obliged to take back the device.
The device is classed as electronic equipment and subject to the WEEE Directive; observe local,
country-specific laws when disposing of the device.
For information on environmentally sound disposal please contact your local authority or a specialist
disposal company.
9
Spare Parts
The in the following listed spare parts can be covered when required about the service address on the
page 2.
Spare part
Remark
Cover
Cover of the hollow- shaft bore (non drive end)
Cable gland
M20 x 1,5
Terminal box cover
Incl. Sealing and screws