Incremental Hollow Shaft Encoder FGH 40
20
FGH40_MANUAL-en_R10(2018-10-31)ID74492.doc
5.6
Dismantling
5.6.1
Safety instruction
Personnel
Dismantling must be carried out by skilled technical staff only.
WARNING!
Observe the safety instructions contained in Chapter 2 when dismantling the device!
NOTES!
Do not use a hammer or similar tool when installing the device due to the risk of damage
occurring to the bearings or coupling!
5.6.2
Dismantling hollow- shaft type FGH 40
Disconnect all electrical cable prior to beginning any work.
To dismantling the encoder follow the instructions given in Chapter 5.5 in the reverse order.
NOTES!
Use the withdrawal device D-53663a (available as an accessory) if you are unable to
remove the device manually from the adapter shaft after having removed the axial
tensioning disc)!
Special tool Withdrawal device
D-53663a
Using the withdrawal device, which is screwed into the withdrawal thread M25 x 0.75 of
the hollow shaft allows you to remove the overspeed switch from the adapter shaft
without risking damage to the bearings.