background image

Page 

23 of 26

Model 298 ADA-Compliant Emergency Telephone

Pub.  42004-304A

f:\standard ioms - current release\42004 instr. manuals\42004-304a.doc

06/02

Additional Information, Canada

Notice

The Canadian Department of Communications label identifies certified equipment.  This certification
means that the equipment meets certain telecommunications network protective, operational and safety
requirements.  The Department does not guarantee the equipment will operate to the user's satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities
of the local telecommunications company.  The equipment must also be installed using an acceptable
method of connection.  In some cases, the company's inside wiring associated with a single line individual
service may be extended by means of a certified connector assembly (telephone extension cord).  The
customer should be aware that compliance with the above condition may not prevent degradation of service
in some situations.

Repairs to some certified equipment should be made by an authorized maintenance facility designated by
the supplier.  Any repairs or alterations made by the user to this equipment, or equipment malfunctions,
may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the ground connections of the power utility, telephone
lines and internal metallic water pipe system, are connected together.  This precaution may be particularly
important in rural areas.

CAUTION

Users should not attempt to make such connections themselves, but should contact the appropriate
electric inspection authority, or electrician, as appropriate.

The RINGER EQUIVALENCE NUMBER (REN) assigned to each terminal device denotes the percentage
of the total load to be connected to a telephone loop that is used by the device, to prevent overloading.  The
termination on a loop may consist of any combination of devices subject only to the requirement that the
total of the REN of all devices does not exceed 5.

The REN for the Model 298 Emergency Telephone is 0.5.

Maintenance

The printed circuit assembly in this telephone is protected from transient voltage spikes across the
telephone line by voltage-limiting devices and a replaceable fuse.  Under normal operating conditions, the
voltage-limiting devices will never have to be replaced; however, the protective fuses are designed to open
during an extended transient voltage condition.  This fuse is mounted on the printed circuit board assembly
(PCBA) 69149-102.

To replace the fuse, remove the power from the unit.  Use a GAI-Tronics Model 233 Tamper-Resistant
Screwdriver (sold separately) to open the front panel of the telephone.  Pry the fuse from the printed circuit
card and replace with a UL-recognized ¼ ampere ceramic slow-blow fuse, available from GAI-Tronics as
the Model 12604-003 Replacement Fuse Kit.

Содержание GAI-Tronics 298

Страница 1: ...r Configuration 6 Polarity Configuration 7 Programming Password Configuration 7 MICROPHONE SENSITIVITY AND SPEAKER VOLUME ADJUSTMENT 8 Programming Instructions 8 REMOTE PROGRAMMING 8 Password Enabled...

Страница 2: ...ACTIVATION 20 AUXILIARY OUTPUT DESIGN EXAMPLES 21 24 V DC Relay Example 21 48 V DC Relay Example 21 User Instructions 22 Additional Information Canada 23 Maintenance 23 TROUBLESHOOTING 25 Symptom 25...

Страница 3: ...lephones are equipped with an auxiliary output to attach peripheral equipment such as beacons video cameras or alarms GAI Tronics emergency telephones have many user programmable features and options...

Страница 4: ...cifically designed for wet locations NEVER touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface USE CAUTION when installing or modify...

Страница 5: ...stomer supplied telephone line surge suppressor on the telephone line if applicable 5 Remove the tapered plug from the top or bottom cable entry hole in the back box and install the customer supplied...

Страница 6: ...he six 10 tamper resistant screws that are provided A Model 233 Tamper Resistant Screwdriver sold separately is required when installing the tamper resistant screws Hardware Configuration The hardware...

Страница 7: ...terminal connected to the tip Non polarity Sensitive Insert the J6 jumper on pins 1 and 2 Polarity Sensitive Insert the J6 jumper on pins 2 and 3 Programming Password Configuration Factory Setting Pa...

Страница 8: ...tating R27 clockwise increases the sensitivity 5 To adjust the speaker volume while the caller is speaking adjust the Volume Control Potentiometer R41 to the desired level Rotating R41 clockwise incre...

Страница 9: ...6 Terminate the programming by placing the touch tone telephone on hook Password Disabled Programming 1 Disable the password protection feature insert the J9 jumper on pins 2 and 3 2 Enable the auto...

Страница 10: ...ameters that are listed in the Programming Table on page 18 A User Settings section has been provided in the Programming Table for the user to record the selected programming parameters It is recommen...

Страница 11: ...Delay 1 0 N N The dial tone delay is the amount of time the unit waits for a dial tone before auto dialing the telephone number 00 infinite 01 15 seconds Note Most applications will utilize the defau...

Страница 12: ...cond dial tone DD represents the telephone number Up to 20 digits can be programmed including the digits For Example If you must dial 9 to access an outside line and you want to assign the number 555...

Страница 13: ...disabled Feature Key Sequence Description Default Ring down Operation KEY SWITCH disabled 1 This option clears the telephone number to prevent auto dialing when the button is pressed Once the button...

Страница 14: ...word and cannot enter programming mode see the Password Disabled Programming section For Example To program the password 1234 enter 1 4 1 2 3 4 2468 PROGRAMMING DISCONNECT OPERATION Several options ar...

Страница 15: ...call duration timer begins when the emergency telephone goes off hook The emergency telephone automatically disconnects after the programmed time out period elapses The user can immediately press the...

Страница 16: ...ed with two different versions of the U9 DTMF Transmitter Emergency telephones manufactured before 4 97 contain the older DTMF Transmitter 5087 All other telephones contain the new DTMF Transmitter 50...

Страница 17: ...Feature Key Sequence Description Default ADA Options 1 8 L This option enables three features call received indicator lamp activation location identification code dialing and the DTMF call disconnect...

Страница 18: ...Dial Tone Delay 11NN 1100 Ring down Operation Key Switch Disabled 1 None Ring down Operation Key Switch Enabled 2 None Password Programming Password Protection 14NNNN 142468 Disconnect Programming Ca...

Страница 19: ...rom the output contact The auxiliary output is disabled when the emergency push button is depressed See Figure 5 and Figure 6 for typical interconnection details of the GAI Tronics 530A or 530FB Beaco...

Страница 20: ...iliary output is polarity sensitive TB2 1 is positive and TB2 2 is negative CAUTION Polarity reversals can damage the auxiliary output CAUTION Use minimal torque on the terminals of TB2 to avoid damag...

Страница 21: ...30 V dc Iload Vload Rload 24 V dc 800 ohms 30 mA Therefore the external voltage must be in the range of Vmin load Vmax drop Vsource Vmax load Vmin drop 19 V 3 V 24 V 30 V 0 25 V 48 V DC Relay Example...

Страница 22: ...telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make ch...

Страница 23: ...ction that the ground connections of the power utility telephone lines and internal metallic water pipe system are connected together This precaution may be particularly important in rural areas CAUTI...

Страница 24: ...Page 24 of 26 Model 298 ADA Compliant Emergency Telephone Pub 42004 304A f standard ioms current release 42004 instr manuals 42004 304a doc 06 02 Figure 8 Low Power Jumper Switch...

Страница 25: ...rovide the appropriate loop current for long cable runs ENABLING 24 VOLT POWER MODE 1 Open the telephone by removing the 6 tamper resistant screws on the front cover of the telephone 2 Being careful n...

Страница 26: ...Electrical Specifications Maximum Voltage Vmax 48 V dc Maximum Loop Current Imax 75 mA Maximum Voltage Drop Vmax drop 3 0 V dc Minimum Voltage Drop Vmin drop 0 25 V dc Polarity TB2 1 positive TB2 2 n...

Страница 27: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...

Отзывы: