Page
19 of 26
Model 298 ADA-Compliant Emergency Telephone
Pub. 42004-304A
f:\standard ioms - current release\42004 instr. manuals\42004-304a.doc
06/02
Auxiliary Output
The auxiliary output enables peripheral equipment (beacons, video cameras, alarms, and so on) to be
activated when the emergency push button is pressed. The auxiliary output is a solid state relay that
optically isolates the control voltage from the output contact. The auxiliary output is disabled when the
emergency push button is depressed.
See Figure 5 and Figure 6 for typical interconnection details of the GAI-Tronics 530A or 530FB Beacon
(sold separately) and the GAI-Tronics 531A Beacon (sold separately). See Figure 7 for typical
interconnection details of relays to the auxiliary output. The relay design guidelines, the Auxiliary Output
Electrical Specifications, and the relay design examples have been provided to aid the user in selecting the
customer-supplied peripheral equipment.
Figure 5. Typical 530A or 530FB Beacon Interconnection