Page
15 of 26
Model 298 ADA-Compliant Emergency Telephone
Pub. 42004-304A
f:\standard ioms - current release\42004 instr. manuals\42004-304a.doc
06/02
Feature
Key
Sequence
Description
Default
Emergency
Push-button
Disconnect
Option
# 1 7
L
The
EMERGENCY
button cannot be used to disconnect a call for
ten seconds after initially pressing the push button. However, the
emergency push button can be used to disconnect calls after the
ten-second push button lockout period elapses when
L
=1. To
prevent the
EMERGENCY
push button from disconnecting the
call, set
L
=0.
For Example
: To enable the
EMERGENCY
push button
disconnect, enter
# 1 7 1
. To disable the
EMERGENCY
push
button disconnect, enter
# 1 7 0
.
0 (Disabled)
Call Time-out
Disconnect
Option
# 1 2
N N
This feature programs the maximum length of a call if no other
disconnect features are used (1-15 minutes, in 1 minute
increments). The call duration timer begins when the emergency
telephone goes off-hook. The emergency telephone automatically
disconnects after the programmed time-out period elapses.
The user can immediately press the
EMERGENCY
button to
reconnect the auto-dial number. This feature helps prevent non-
emergency calls from tying up emergency lines for long lengths
of time.
For Example
: To make the maximum call length two minutes,
enter
# 1 2 0 2
. To make the maximum call length infinite, such
as no automatic disconnect, enter
# 1 2 0 0
.
05
(5 minutes)
Dial Tone
Disconnect
Option
# 1 9
L
WARNING
Use this option only if no other disconnect options are
available.
If this option is enabled, the telephone automatically terminates a
call if it detects a dial tone continuously for 10 seconds, such as if
the called party hangs up. To enable the dial tone disconnect,
L
=1. To disable the dial tone disconnect,
L
=0.
For Example
: To enable the dial tone disconnect, enter
# 1 9 1
.
To disable the dial tone disconnect, enter
# 1 9 0
.
0 (Disabled)
DTMF
Disconnect
Option
See the ADA Programming section for details (page 16).