![HUAYUAN POWERCUT105 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/huayuan/powercut105/powercut105_manual-instruction_2179862029.webp)
- 25 -
Secondary menu function
:
Code
Content
Adj.
range
Unit
De
fault
Remarks
P02
Gas post flow t
ime set
20
~
100
s
20
P04
Cutting time se
t
1
~
999
min
999
If reach the set value, t
here will be warning or
controlling, cutting stop
P05
Penetration tim
es set
1
~
999
times
999
P06
Cutting time lef
t display
-
min
-
P07
Penetration tim
es left display
-
times
-
P08
Monitor
control switch
0 or 1
-
0
On (1): Cannot cut after
warning
Off (0)
:
Can cut after
warning
P09
Monitor
parameter reset
Reset
(
1
)
Keep
(
0
)
-
0
1 means reset
immediately, the cutting
time and arc striking time
rest
Parameter
adjust knob
Parameter or
menu code
display
Gas test
Operation mode select
(
lock/unlock
)
Cutting mode
select
(
gouging/standard
cutting/continuous
arc strike cutting
)
Indicator
Function
selection
display
Gas pressure adjust
Содержание POWERCUT105