- 10 -
External characteristic curve
Power source installation size
2.Requirements of gas supply
The Air in above table should accordance with the ISO standard 8573.1 grade, as following:
⑴
Solid particle: grade 1, 0.1~0.5μm particle can’t be more than 100pc, 0.5
~
5.0μm
particle can’t be more than 1pc per 1CBM air
⑵
Temperature: grade 4, humidity pressure must be less or equal to 3
℃
⑶
Oil: grade 2, the density of the oil in air can’t be more than 0.1mg/m
3
Requirement for gas quality and pressure
Gas
Quality
Pressure ±10%
N2
Purity≥99.99%
Clean, dry and oil-free
Cutting
:
5.9bar / 220slpm
Gouging
:
4.8bar / 220slpm
AIR
Clean, dry and oil-free